Omega OMB-DAQ-2408-2AO USB Data Acquisition Module, 16-channels, 2 analog outputs

Model: OMB-DAQ-2408-2AO

Omega OMB-DAQ-2408-2AO USB Data Acquisition Module, 16-channels, 2 analog outputs

Model: OMB-DAQ-2408-2AO

Designed for highly accurate temperature and voltage measurement, this USB data acquisition module provides 16 single-ended or 8 differential analog inputs at 24-bit resolution, up to 1 kS/s. It accepts type J, K, T, E, R, S, B, N thermocouples or voltage from ±0.078 to ±10 V, with 500 V DC isolation, 8 digital I/O, two counters, and two 16-bit ±10 V analog outputs.

Designed for highly accurate temperature and voltage measurement, this USB data acquisition module provides 16 single-ended or 8 differential analog inputs at 24-bit resolution, up to 1 kS/s. It accepts type J, K, T, E, R, S, B, N thermocouples or voltage from ±0.078 to ±10 V, with 500 V DC isolation, 8 digital I/O, two counters, and two 16-bit ±10 V analog outputs.

Your Price $1154.92 USD
Availability 2 to 3 Weeks
Quantity

OMEGA OMB-DAQ-2408-2AO Offers

The OMB-DAQ-2408 Series are multifunction DAQ devices designed for highly-accurate voltage or temperature measurements. Each device features up to 16 single ended (SE)/8 differential (DIFF) analog inputs. Each device includes 8 digital I/O and two counter inputs. The OMB-DAQ-2408-2AO also features two analog outputs. Each device in the series offers 24-bit resolution for ultra-accurate voltage or thermocouple measurements.

Each device includes 16 SE/8 DIFF analog inputs which you can configure for voltage or thermocouple input on a per-channel basis. Eight software-selectable voltage input ranges are provided. You can configure these ranges on a per-channel basis from ±10 V to ±0.078 V. When measuring thermocouples, configure analog inputs in DIFF mode. All devices also include open thermocouple detection to identify improperly working thermocouples.

The OMB-DAQ-2408-2AO includes two 16-bit analog outputs. Each output has a ±10 V range. Both outputs can be updated at a rate of up to 500 S/s per channel; one output can be updated at a rate of 1 kS/s.

Features

  • Measures thermocouples or voltage
  • Up to 16 analog inputs
  • 24-bit resolution analog input
  • Up to 1 kS/s sampling
  • Two counters
  • Supports thermocouple types J, K, T, E, R, S, B, N
  • Built-in cold junction compensation and open thermocouple detection
  • Eight digital I/O
  • Up to 2 analog outputs
  • 500 V DC isolation between field wiring and the USB interface

Applications

  • Highly accurate multi-channel thermocouple measurement
  • Per-channel voltage measurement across eight selectable ranges
  • Generating analog output signals for control and stimulus
  • Event counting with the two 32-bit counters
  • Process data acquisition and logging over USB

OMEGA OMB-DAQ-2408-2AO Specifications

A/D converter type ADS1256, 24-bit Sigma Delta
A/D data rates 3750 S/s, 2000 S/s, 1000 S/s, 500 S/s, 100 S/s, 60 S/s, 50 S/s, 25 S/s, 10 S/s, 5 S/s, 2.5 S/s
Throughput, single channel 2.5 to 1102.94 S/s
Throughput, multiple channels 0.16 to 1102.94 Hz
Number of channels Up to 16 channels individually software-selectable as single ended (SE) or differential (DIFF); thermocouples require differential mode
Input isolation 500 V DC minimum between field wiring and USB interface
Input voltage range, thermocouple mode ±0.078125 V
Input voltage range, voltage mode (software-selectable) ±10 V, ±5 V, ±2.5 V, ±1.25 V, ±0.625 V, ±0.3125 V, ±0.15625 V, ±0.078125 V
Absolute maximum input voltage CxH-CxL relative to GND ±22 V maximum (power on), ±10 V maximum (power off)
Input impedance 10 MΩ (power on), 390 Ω (power off)
Input leakage current ±20 nA
Maximum working voltage (signal + common mode), voltage mode ±10.25 V maximum
Common mode rejection ratio, thermocouple mode (fIN = 60 Hz) 110 dB
Common mode rejection ratio, voltage mode (fIN = 60 Hz, all input ranges) 90 dB
ADC resolution 24 bits
Crosstalk Adjacent channels, 100 dB
Channel gain queue Up to 64 elements, software-selectable channel and range
Warm-up time 45 minutes minimum
Open thermocouple detect Software-selectable for each channel
CJC sensor accuracy 15 to 35°C: ±0.5°C typical; 0 to 55°C: ±1.0°C maximum
Analog input DC voltage accuracy, ±10 V Gain error ±0.0037% of reading, offset error 50 µV, INL error ±0.0008, accuracy absolute 500 µV
Type J thermocouple accuracy Maximum: ±2.572 @ -210°C, ±0.935 @ 0°C, ±1.869 @ 1200°C (°C); includes CJC and linearization error
Type K thermocouple accuracy Maximum: ±2.917 @ -210°C, ±1.017 @ 0°C, ±2.478 @ 1372°C (°C)
Type T thermocouple accuracy Maximum: ±2.821 @ -200°C, ±1.050 @ 0°C, ±0.957 @ 400°C (°C)
Type E thermocouple accuracy Maximum: ±2.413 @ -200°C, ±1.069 @ 0°C, ±1.575 @ 1000°C (°C)
Type R thermocouple accuracy Maximum: ±4.826 @ -50°C, ±2.117 @ 250°C, ±2.842 @ 1768°C (°C)
Type S thermocouple accuracy Maximum: ±4.510 @ -50°C, ±2.165 @ 250°C, ±3.187 @ 1768°C (°C)
Type B thermocouple accuracy Maximum: ±5.489 @ 250°C, ±2.283 @ 700°C, ±2.202 @ 1820°C (°C)
Type N thermocouple accuracy Maximum: ±3.480 @ -200°C, ±1.201 @ 0°C, ±1.991 @ 1300°C (°C)
Digital to analog converter DAC8552
Number of channels 2
Resolution 16-bits
Output range, calibrated ±10 V
Output current AOUTx pins, ±5.0 mA maximum
Throughput Single-channel: 1000 S/s maximum, system-dependent; Multi-channel: 1000 S/s /#ch maximum, system-dependent
Differential non linearity ±0.25 LSB typical, ±1 LSB maximum
Settling time To rated accuracy, 10 V step, 75 µs
Slew rate 1.0 V/µs
Number of I/O 8 channels
Configuration Each DIO bit can be independently read from (DIN) or written to (DOUT)
Number of channels 2 channels
Resolution 32-bits
Counter type Event counter
Input type Schmitt trigger, rising edge triggered
Input frequency 1 MHz, maximum
Microcontroller One high-performance 8-bit RISC microcontroller with USB interface (non-isolated); one high-performance 16-bit RISC microcontroller for measurements (isolated)
Supply current Quiescent current, 275 mA
5 V user output voltage range Available at terminal block pin 40, 4.75 to 5.25 V
5 V user output current Available at terminal block pin 40, 10 mA maximum
Isolation Measurement system to PC, 500 V DC minimum
USB device type USB 2.0 (full-speed)
Device compatibility USB 1.1, USB 2.0
USB cable length 9.8' (3 m) maximum
Screw terminal connector type Fixed screw terminal
Wire gauge range 16 to 30 AWG
Operating temperature range 32 to 122°F (0 to 50°C)
Storage temperature range -40 to 185°F (-40 to 85°C)
Humidity 0 to 90% RH non-condensing
Dimensions 5.00 x 3.53 x 1.40" (127 x 89.9 x 35.6 mm)
Weight Weight: 5.6 oz (160 g)

What's included with the OMEGA OMB-DAQ-2408-2AO

  • OMB-DAQ-2408-2AO Data Acquisition Module
  • Quick Start Guide
  • 2 M (6') USB Cable
  • TracerDAQ Software and Operator's Manual On CD

Ask a question about Omega OMB-DAQ-2408-2AO USB Data Acquisition Module, 16-channels, 2 analog outputs

Customer Reviews for the OMEGA OMB-DAQ-2408-2AO

OMEGA OMB-DAQ-2408-2AO Offers

The OMB-DAQ-2408 Series are multifunction DAQ devices designed for highly-accurate voltage or temperature measurements. Each device features up to 16 single ended (SE)/8 differential (DIFF) analog inputs. Each device includes 8 digital I/O and two counter inputs. The OMB-DAQ-2408-2AO also features two analog outputs. Each device in the series offers 24-bit resolution for ultra-accurate voltage or thermocouple measurements.

Each device includes 16 SE/8 DIFF analog inputs which you can configure for voltage or thermocouple input on a per-channel basis. Eight software-selectable voltage input ranges are provided. You can configure these ranges on a per-channel basis from ±10 V to ±0.078 V. When measuring thermocouples, configure analog inputs in DIFF mode. All devices also include open thermocouple detection to identify improperly working thermocouples.

The OMB-DAQ-2408-2AO includes two 16-bit analog outputs. Each output has a ±10 V range. Both outputs can be updated at a rate of up to 500 S/s per channel; one output can be updated at a rate of 1 kS/s.

Features

  • Measures thermocouples or voltage
  • Up to 16 analog inputs
  • 24-bit resolution analog input
  • Up to 1 kS/s sampling
  • Two counters
  • Supports thermocouple types J, K, T, E, R, S, B, N
  • Built-in cold junction compensation and open thermocouple detection
  • Eight digital I/O
  • Up to 2 analog outputs
  • 500 V DC isolation between field wiring and the USB interface

Applications

  • Highly accurate multi-channel thermocouple measurement
  • Per-channel voltage measurement across eight selectable ranges
  • Generating analog output signals for control and stimulus
  • Event counting with the two 32-bit counters
  • Process data acquisition and logging over USB

OMEGA OMB-DAQ-2408-2AO Specifications

A/D converter type ADS1256, 24-bit Sigma Delta
A/D data rates 3750 S/s, 2000 S/s, 1000 S/s, 500 S/s, 100 S/s, 60 S/s, 50 S/s, 25 S/s, 10 S/s, 5 S/s, 2.5 S/s
Throughput, single channel 2.5 to 1102.94 S/s
Throughput, multiple channels 0.16 to 1102.94 Hz
Number of channels Up to 16 channels individually software-selectable as single ended (SE) or differential (DIFF); thermocouples require differential mode
Input isolation 500 V DC minimum between field wiring and USB interface
Input voltage range, thermocouple mode ±0.078125 V
Input voltage range, voltage mode (software-selectable) ±10 V, ±5 V, ±2.5 V, ±1.25 V, ±0.625 V, ±0.3125 V, ±0.15625 V, ±0.078125 V
Absolute maximum input voltage CxH-CxL relative to GND ±22 V maximum (power on), ±10 V maximum (power off)
Input impedance 10 MΩ (power on), 390 Ω (power off)
Input leakage current ±20 nA
Maximum working voltage (signal + common mode), voltage mode ±10.25 V maximum
Common mode rejection ratio, thermocouple mode (fIN = 60 Hz) 110 dB
Common mode rejection ratio, voltage mode (fIN = 60 Hz, all input ranges) 90 dB
ADC resolution 24 bits
Crosstalk Adjacent channels, 100 dB
Channel gain queue Up to 64 elements, software-selectable channel and range
Warm-up time 45 minutes minimum
Open thermocouple detect Software-selectable for each channel
CJC sensor accuracy 15 to 35°C: ±0.5°C typical; 0 to 55°C: ±1.0°C maximum
Analog input DC voltage accuracy, ±10 V Gain error ±0.0037% of reading, offset error 50 µV, INL error ±0.0008, accuracy absolute 500 µV
Type J thermocouple accuracy Maximum: ±2.572 @ -210°C, ±0.935 @ 0°C, ±1.869 @ 1200°C (°C); includes CJC and linearization error
Type K thermocouple accuracy Maximum: ±2.917 @ -210°C, ±1.017 @ 0°C, ±2.478 @ 1372°C (°C)
Type T thermocouple accuracy Maximum: ±2.821 @ -200°C, ±1.050 @ 0°C, ±0.957 @ 400°C (°C)
Type E thermocouple accuracy Maximum: ±2.413 @ -200°C, ±1.069 @ 0°C, ±1.575 @ 1000°C (°C)
Type R thermocouple accuracy Maximum: ±4.826 @ -50°C, ±2.117 @ 250°C, ±2.842 @ 1768°C (°C)
Type S thermocouple accuracy Maximum: ±4.510 @ -50°C, ±2.165 @ 250°C, ±3.187 @ 1768°C (°C)
Type B thermocouple accuracy Maximum: ±5.489 @ 250°C, ±2.283 @ 700°C, ±2.202 @ 1820°C (°C)
Type N thermocouple accuracy Maximum: ±3.480 @ -200°C, ±1.201 @ 0°C, ±1.991 @ 1300°C (°C)
Digital to analog converter DAC8552
Number of channels 2
Resolution 16-bits
Output range, calibrated ±10 V
Output current AOUTx pins, ±5.0 mA maximum
Throughput Single-channel: 1000 S/s maximum, system-dependent; Multi-channel: 1000 S/s /#ch maximum, system-dependent
Differential non linearity ±0.25 LSB typical, ±1 LSB maximum
Settling time To rated accuracy, 10 V step, 75 µs
Slew rate 1.0 V/µs
Number of I/O 8 channels
Configuration Each DIO bit can be independently read from (DIN) or written to (DOUT)
Number of channels 2 channels
Resolution 32-bits
Counter type Event counter
Input type Schmitt trigger, rising edge triggered
Input frequency 1 MHz, maximum
Microcontroller One high-performance 8-bit RISC microcontroller with USB interface (non-isolated); one high-performance 16-bit RISC microcontroller for measurements (isolated)
Supply current Quiescent current, 275 mA
5 V user output voltage range Available at terminal block pin 40, 4.75 to 5.25 V
5 V user output current Available at terminal block pin 40, 10 mA maximum
Isolation Measurement system to PC, 500 V DC minimum
USB device type USB 2.0 (full-speed)
Device compatibility USB 1.1, USB 2.0
USB cable length 9.8' (3 m) maximum
Screw terminal connector type Fixed screw terminal
Wire gauge range 16 to 30 AWG
Operating temperature range 32 to 122°F (0 to 50°C)
Storage temperature range -40 to 185°F (-40 to 85°C)
Humidity 0 to 90% RH non-condensing
Dimensions 5.00 x 3.53 x 1.40" (127 x 89.9 x 35.6 mm)
Weight Weight: 5.6 oz (160 g)

What's included with the OMEGA OMB-DAQ-2408-2AO

  • OMB-DAQ-2408-2AO Data Acquisition Module
  • Quick Start Guide
  • 2 M (6') USB Cable
  • TracerDAQ Software and Operator's Manual On CD

Ask a question about Omega OMB-DAQ-2408-2AO USB Data Acquisition Module, 16-channels, 2 analog outputs

Customer Reviews for the OMEGA OMB-DAQ-2408-2AO

More OMEGA Products