Image is for reference only, refer to product info for complete details.
Measuring across -148 to 212°F (-100 to 100°C), this ultra precise RTD sensor uses a Pt100 platinum element at Class A per IEC 60751 in a 0.125 x 6" probe 4-wire with stripped leads. It is used for extruder temperature monitoring.
Measuring across -148 to 212°F (-100 to 100°C), this ultra precise RTD sensor uses a Pt100 platinum element at Class A per IEC 60751 in a 0.125 x 6" probe 4-wire with stripped leads. It is used for extruder temperature monitoring.
Omega's Ultra-Precise RTD sensors are used in a wide variety of applications where accuracy and precise temperature measurement means the difference between failure and success.
Features
Applications
| Series | P Series |
| Type | Ultra Precise RTD Sensor |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | Class A per IEC 60751 |
| Temperature range | -148 to 212°F (-100 to 100°C) |
| Wiring | 4 wire |
| Sheath material | 304 SS |
| Connection | Stripped Leads |
| Cable | 3.28' (1 m) of 4-wire, #26 AWG stranded cable with stripped ends standard (see table for insulation options) |
| Diameters | 6 and 3 mm (1/4 and 1/8" (3.2 mm)) Diameters |
| Mounting Threads | A Range of Mounting Threads and Cable Materials Available (1/4 NPT, 3/8 NPT and 1/2 NPT; metric M6x1, M8x1, M10x1) |
| Standard Probe Length | 6" (15.2 cm) Probe Length (standard) / 150 mm (metric) |
| Air Sensor (PL) Sheath | Air Flow Holes in Sheath; Vent holes at the tip of the sensor allow the air or gas to directly pass around the RTD element (PL air and gas models) |
| Interchangeability in °C — Class A | -50: 0.25; 0: 0.15; 100: 0.35; 200: 0.55; 250: 0.65; 300: 0.75; 350: 0.85; 400: 0.95; 450: 1.05; -100: 0.35 |
| Interchangeability in °C — 1⁄3 DIN | -50: 0.18; 0: 0.10; 100: 0.27; 200: 0.43; 250: 0.52 |
| Interchangeability in °C — 1⁄10 DIN | 0: 0.03; 100: 0.08 |
| Cable Option Range — PVC Insulated | -20 to 212°F (-29 to 100°C) |
| Cable Option Range — PFA Insulation | -148 to 482°F (-100 to 250°C) |
| Cable Option Range — Fiberglass Insulation | -99 to 753°F (-73 to 400°C) |
| Cable Option Range — Silicone Insulated | -58 to 392°F (-50 to 200°C) |
| Probe dimensions | 0.125 x 6" (3.2 mm x 15.2 cm) |
Click on a category to view a selection of compatible accessories with the Omega PM Series Ultra Precise RTD Sensor, Pt100, class A, 0.125 x 6" probe, 4-wire, 3' cable, stripped leads.
| Series | P Series |
| Type | Ultra Precise RTD Sensor |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | Class A per IEC 60751 |
| Temperature range | -148 to 212°F (-100 to 100°C) |
| Wiring | 4 wire |
| Sheath material | 304 SS |
| Connection | Stripped Leads |
| Cable | 3.28' (1 m) of 4-wire, #26 AWG stranded cable with stripped ends standard (see table for insulation options) |
| Diameters | 6 and 3 mm (1/4 and 1/8" (3.2 mm)) Diameters |
| Mounting Threads | A Range of Mounting Threads and Cable Materials Available (1/4 NPT, 3/8 NPT and 1/2 NPT; metric M6x1, M8x1, M10x1) |
| Standard Probe Length | 6" (15.2 cm) Probe Length (standard) / 150 mm (metric) |
| Air Sensor (PL) Sheath | Air Flow Holes in Sheath; Vent holes at the tip of the sensor allow the air or gas to directly pass around the RTD element (PL air and gas models) |
| Interchangeability in °C — Class A | -50: 0.25; 0: 0.15; 100: 0.35; 200: 0.55; 250: 0.65; 300: 0.75; 350: 0.85; 400: 0.95; 450: 1.05; -100: 0.35 |
| Interchangeability in °C — 1⁄3 DIN | -50: 0.18; 0: 0.10; 100: 0.27; 200: 0.43; 250: 0.52 |
| Interchangeability in °C — 1⁄10 DIN | 0: 0.03; 100: 0.08 |
| Cable Option Range — PVC Insulated | -20 to 212°F (-29 to 100°C) |
| Cable Option Range — PFA Insulation | -148 to 482°F (-100 to 250°C) |
| Cable Option Range — Fiberglass Insulation | -99 to 753°F (-73 to 400°C) |
| Cable Option Range — Silicone Insulated | -58 to 392°F (-50 to 200°C) |
| Probe dimensions | 0.125 x 6" (3.2 mm x 15.2 cm) |
Click on a category to view a selection of compatible accessories with the Omega PM Series Ultra Precise RTD Sensor, Pt100, class A, 0.125 x 6" probe, 4-wire, 3' cable, stripped leads.