Suited for multi-channel process data logging, this paperless recorder accepts six thermocouple inputs and integrates measurement, display, alarm, and datalogging in one slim 7" (17.8 cm) touch screen instrument. It records at up to 1 Hz with 0.2% FS accuracy, stores history in 150 MB of internal memory, and exports data to USB. It mounts in a panel with a 40 mm slim depth.
Suited for multi-channel process data logging, this paperless recorder accepts six thermocouple inputs and integrates measurement, display, alarm, and datalogging in one slim 7" (17.8 cm) touch screen instrument. It records at up to 1 Hz with 0.2% FS accuracy, stores history in 150 MB of internal memory, and exports data to USB. It mounts in a panel with a 40 mm slim depth.
The RDA Paperless Recorder Series is a value priced large format touch screen datalogger that integrates measurement, display, alarm, and datalogging into one slim instrument. The RDA Series is available in both 5'' and 7'' display models. The instrument is easy to install and requires no external HMI. Depending on the model, the RDA Series can support 2, 4 or up to 6 input channels with either thermocouple or RTD input type with 0.2% FS measuring accuracy. Each channel can have independent input specification, with square-root, multiplication, addition and subtraction. All channels are equipped with digital adjustment and filtering functions.
The RDA Series provides a real time trend records via trend graph or bar graph. History and alarm records can be reviewed in the logger itself with 150MB of internal storage or exported to external USB storage device. The RDA-740 and RDA-760 models have a slim installation depth of 40mm of for use where installation space is limited.
Features
Applications
| Display | Color TFT True Color, 7 inches (177.8mm) diagonal |
| Resolution | 800*480 |
| Backlit | Long-life LED |
| Input method | Screen touching |
| Touch screen | Four-wire resistive |
| Storage | 150MB |
| Recording interval | 1, 2, 3, 4, etc. user defined (seconds) |
| Input type | Six thermocouples K, S, R, E, J, T, B, N, WRe5-WRe26 |
| Measurement accuracy | 0.2% FS ±1 digit. Internal cold junction compensation (CJC) will require an additional 1°C CJC error to be taken into consideration. The stated accuracy for type B thermocouple is only guaranteed between 600~1800°C (+1112 ~ +3272°F). |
| Response time | ≤1.5 seconds (digital filter parameter dL is set as 0 or 1) |
| Temperature drift | ≤0.01%FS/°C (Typical 50ppm/°C) |
| Measuring range, Type K | -58 to 2372°F (-50 to 1300°C) |
| Measuring range, Type S | -58 to 3092°F (-50 to 1700°C) |
| Measuring range, Type R | -58 to 3092°F (-50 to 1700°C) |
| Measuring range, Type T | -328 to 662°F (-200 to 350°C) |
| Measuring range, Type E | -328 to 1472°F (-200 to 800°C) |
| Measuring range, Type J | 32 to 1472°F (0 to 800°C) |
| Measuring range, Type B | 32 to 1832°F (0 to 1000°C) |
| Measuring range, Type N | 392 to 3272°F (200 to 1800°C) |
| Measuring range, WRe3~WRe5 | 32 to 2372°F (0 to 1300°C) |
| Measuring range, WRe5~WRe26 | 32 to 4172°F (0 to 2300°C) |
| Electromagnetic compatibility (EMC) | 4KV/5KHz according to IEC61000-4-4 (Electrical Fast Transient); 4KV according to IEC61000-4-5 (Electrical Surge) |
| Isolation withstanding voltage | Among power, relay contact or signal terminals 2300VDC. Among isolated electroweak terminals 600 V |
| Power supply | 100~240 V AC, -15%, +10% / 50~60 Hz |
| Power consumption | ≤5 W |
| Operating temperature | 14 to 140°F (-10 to 60°C) |
| Humidity | ≤ 90%RH |
| Storage temperature | -4 to 176°F (-20 to 80°C) |
| Cooling method | Natural air cooling |
| Dimensions | External size (W x H x D): 7.99 x 6.10 x 1.57" (203 x 155 x 40 mm) Installation opening size (W x H): 7.56 x 5.47" (192 x 139 mm) |
| Weight | Weight: 1.54 lbs (0.7 kg) |
| Display | Color TFT True Color, 7 inches (177.8mm) diagonal |
| Resolution | 800*480 |
| Backlit | Long-life LED |
| Input method | Screen touching |
| Touch screen | Four-wire resistive |
| Storage | 150MB |
| Recording interval | 1, 2, 3, 4, etc. user defined (seconds) |
| Input type | Six thermocouples K, S, R, E, J, T, B, N, WRe5-WRe26 |
| Measurement accuracy | 0.2% FS ±1 digit. Internal cold junction compensation (CJC) will require an additional 1°C CJC error to be taken into consideration. The stated accuracy for type B thermocouple is only guaranteed between 600~1800°C (+1112 ~ +3272°F). |
| Response time | ≤1.5 seconds (digital filter parameter dL is set as 0 or 1) |
| Temperature drift | ≤0.01%FS/°C (Typical 50ppm/°C) |
| Measuring range, Type K | -58 to 2372°F (-50 to 1300°C) |
| Measuring range, Type S | -58 to 3092°F (-50 to 1700°C) |
| Measuring range, Type R | -58 to 3092°F (-50 to 1700°C) |
| Measuring range, Type T | -328 to 662°F (-200 to 350°C) |
| Measuring range, Type E | -328 to 1472°F (-200 to 800°C) |
| Measuring range, Type J | 32 to 1472°F (0 to 800°C) |
| Measuring range, Type B | 32 to 1832°F (0 to 1000°C) |
| Measuring range, Type N | 392 to 3272°F (200 to 1800°C) |
| Measuring range, WRe3~WRe5 | 32 to 2372°F (0 to 1300°C) |
| Measuring range, WRe5~WRe26 | 32 to 4172°F (0 to 2300°C) |
| Electromagnetic compatibility (EMC) | 4KV/5KHz according to IEC61000-4-4 (Electrical Fast Transient); 4KV according to IEC61000-4-5 (Electrical Surge) |
| Isolation withstanding voltage | Among power, relay contact or signal terminals 2300VDC. Among isolated electroweak terminals 600 V |
| Power supply | 100~240 V AC, -15%, +10% / 50~60 Hz |
| Power consumption | ≤5 W |
| Operating temperature | 14 to 140°F (-10 to 60°C) |
| Humidity | ≤ 90%RH |
| Storage temperature | -4 to 176°F (-20 to 80°C) |
| Cooling method | Natural air cooling |
| Dimensions | External size (W x H x D): 7.99 x 6.10 x 1.57" (203 x 155 x 40 mm) Installation opening size (W x H): 7.56 x 5.47" (192 x 139 mm) |
| Weight | Weight: 1.54 lbs (0.7 kg) |