Onset HOBO UX90-004M Motor On/Off Data Logger, 512 KB

Model: UX90-004M

Onset HOBO UX90-004M Motor On/Off Data Logger, 512 KB

Model: UX90-004M

Records motor on and off conditions within an AC magnetic field with its internal sensor or with external sensing devices it uses mechanical contact closures. Expanded 512KB memory version capable of over 346,795 measurements.

Records motor on and off conditions within an AC magnetic field with its internal sensor or with external sensing devices it uses mechanical contact closures. Expanded 512KB memory version capable of over 346,795 measurements.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Onset HOBO UX90-004 Motor On/Off Data Logger, 128KB-

Onset HOBO UX90-004 Motor On/Off Data Logger, 128KB

Model: UX90-004

Records motor on and off conditions within an AC magnetic field with its internal sensor or with external sensing devices it uses mechanical contact closures. Standard 128 KB memory model capable of 84,650 measurements.


Not what you're looking for? Let’s do a search and help you find what you need.


Onset HOBO UX90-004M Offers

The award-winning HOBO UX90 Series is the industry's lowest-cost, most comprehensive family of "time-of-use" data loggers. The new toolbox suite includes LCD-display data loggers for measuring motor on/off status, electronic pulses, state changes, and occupancy and light-use patterns. Leveraging patent-pending technology, HOBO UX90 data loggers streamline energy audits and make field deployment fast and reliable.

Features

  • Dual internal motor sensors gives better sensitivity for well-shielded motors
  • External input for measuring mechanical contact closures when signal strength is low
  • Auto-calibration of ON and OFF thresholds ensures reliable readings
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

Applications

Application

  • Energy Performance Monitoring
  • Monitoring Building Efficiency
  • Utilities Monitoring

Onset HOBO UX90-004M Specifications

External Contact Input Electronic Solid State Switch Closure or Logic Driven Voltage Output
Range 0 to 3 V DC (USB Powered), 0 to 2.5 V DC (Battery Powered)
Light Threshold > 65 lux
Resolution Pulse: 1 Pulse
Runtime: 1 Second
State and Event: 1 State or Event
Time Accuracy ±1 Minute Per Month at 25°C (77°F) (See Plot A)
Battery Life 1 Year Typical Use
Memory 512 KB (346,795 Measurements, Maximum)
Download Type USB 2.0 Interface
Download Time 10 Seconds For 128 KB; 30 Seconds For 512 KB
Logging -20 to 70°C (-4 to 158°F)
0 to 95% RH (Non-Condensing)
Launch/Readout 0 to 50°C (32 to 122°F) Per USB Specification
LCD LCD is Visible From: 0 to 50°C (32 to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size 3.66 x 8.48 x 1.52 cm (1.44 x 3.34 x 0.6")
Weight 30 g (1.06 oz)
Environmental Rating IP50
Click here for complete specifications on the Onset HOBO UX90-004M

What's included with the Onset HOBO UX90-004M

  • HOBO UX-90-004M Motor On/Off Data Logger
  • Command™ Strip
  • Double-Sided Tape
  • Hook & Loop Strap

Click on a category to view a selection of compatible accessories with the Onset HOBO UX90-004M Motor On/Off Data Logger, 512 KB.

Onset HOBO CSV-A8 AC Current Switch Sensor CSV-A8
For use with any state channel on UX-120-xxxx, U9-001 or U11-001 loggers. Installs around a current-carrying wire to provide a relay signal indications equipment on/off.




Onset HOBO BHW-PRO-DLD Onset HOBOware PRO Software v.3.x, Mac/Windows download BHW-PRO-DLD
HOBOware software is used for launching, reading out, and plotting data from HOBO® data loggers. With HOBOware, you can also check logger status, filter and export data, save changes to graphs in project files, and scale data with the Linear Scaling and Pulse Scaling data assistants.




Ask a question about Onset HOBO UX90-004M Motor On/Off Data Logger, 512 KB

Customer Reviews for the Onset HOBO UX90-004M

Onset HOBO UX90-004M Offers

The award-winning HOBO UX90 Series is the industry's lowest-cost, most comprehensive family of "time-of-use" data loggers. The new toolbox suite includes LCD-display data loggers for measuring motor on/off status, electronic pulses, state changes, and occupancy and light-use patterns. Leveraging patent-pending technology, HOBO UX90 data loggers streamline energy audits and make field deployment fast and reliable.

Features

  • Dual internal motor sensors gives better sensitivity for well-shielded motors
  • External input for measuring mechanical contact closures when signal strength is low
  • Auto-calibration of ON and OFF thresholds ensures reliable readings
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

Applications

Application

  • Energy Performance Monitoring
  • Monitoring Building Efficiency
  • Utilities Monitoring

Onset HOBO UX90-004M Specifications

External Contact Input Electronic Solid State Switch Closure or Logic Driven Voltage Output
Range 0 to 3 V DC (USB Powered), 0 to 2.5 V DC (Battery Powered)
Light Threshold > 65 lux
Resolution Pulse: 1 Pulse
Runtime: 1 Second
State and Event: 1 State or Event
Time Accuracy ±1 Minute Per Month at 25°C (77°F) (See Plot A)
Battery Life 1 Year Typical Use
Memory 512 KB (346,795 Measurements, Maximum)
Download Type USB 2.0 Interface
Download Time 10 Seconds For 128 KB; 30 Seconds For 512 KB
Logging -20 to 70°C (-4 to 158°F)
0 to 95% RH (Non-Condensing)
Launch/Readout 0 to 50°C (32 to 122°F) Per USB Specification
LCD LCD is Visible From: 0 to 50°C (32 to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size 3.66 x 8.48 x 1.52 cm (1.44 x 3.34 x 0.6")
Weight 30 g (1.06 oz)
Environmental Rating IP50
Click here for complete specifications on the Onset HOBO UX90-004M

What's included with the Onset HOBO UX90-004M

  • HOBO UX-90-004M Motor On/Off Data Logger
  • Command™ Strip
  • Double-Sided Tape
  • Hook & Loop Strap

Click on a category to view a selection of compatible accessories with the Onset HOBO UX90-004M Motor On/Off Data Logger, 512 KB.

Onset HOBO CSV-A8 AC Current Switch Sensor CSV-A8
For use with any state channel on UX-120-xxxx, U9-001 or U11-001 loggers. Installs around a current-carrying wire to provide a relay signal indications equipment on/off.




Onset HOBO BHW-PRO-DLD Onset HOBOware PRO Software v.3.x, Mac/Windows download BHW-PRO-DLD
HOBOware software is used for launching, reading out, and plotting data from HOBO® data loggers. With HOBOware, you can also check logger status, filter and export data, save changes to graphs in project files, and scale data with the Linear Scaling and Pulse Scaling data assistants.




Ask a question about Onset HOBO UX90-004M Motor On/Off Data Logger, 512 KB

Customer Reviews for the Onset HOBO UX90-004M

More Onset HOBO Products