Digital analog bargraph and high resolution of 10µA.
Digital analog bargraph and high resolution of 10µA.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
This AC leakage current tester features a large 4000 count LCD display and 40 segment digital analog bargraph. The ST-9809 includes leads for voltage testing and a protective boot for added durability in the field.
Features
| Current | |
| Range | 40mA, 400mA, 4A, 40A, 100A |
| Accuracy (50-60Hz) | 40mA: ±(1.0% +0.5mA) 400mA: ±(3.0% +5.0mA) 4A: ±(4.0% +0.1A) 40A: ±(4.0% +1.0A) 100A: ±(5.0% +1.0A) |
| Resolution | 10µA, 100µA, 1mA, 10mA, 100mA |
| Voltage | |
| Range | 400V |
| Accuracy (50-60Hz) | ±(1.5% +2 dgts.) |
| Resolution | 0.1V |
| Resistance | |
| Range | 40 to 400Ω |
| Accuracy | ±(1.0% +2 dgts.) |
| Resolution | 0.1Ω |
| General Specifications | |
| Range Selection | Manual |
| Sampling Time | Display: 2x / sec. Bargraph: 20x / sec. |
| Display | 4,000 count LCD display |
| Display Hold | Yes |
| Max/Min | Yes |
| Zero Push Button Adjustment | Yes |
| Relative Mode | Yes |
| Analog Bargraph | Yes (40 segment) |
| Continuity Check | Audible signal if resistance <40Ω |
| Auto Shut Off | Yes (after 30 minutes, off) |
| Power Supply | 9V Battery |
| Low Battery Indicator | Yes |
| Jaw Opening | 1.2" (30mm) |
| Overvoltage Category | CAT. II 600V |
| Operating Temperature | 14 to 122°F (-10 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Dimensions | 8.3 x 2.4 x 1.4" (210 x 62 x 36 mm) |
| Weight | 7.1 oz (200g) |
Click on a category to view a selection of compatible accessories with the REED ST-9809 AC Leakage Current Tester.
| Current | |
| Range | 40mA, 400mA, 4A, 40A, 100A |
| Accuracy (50-60Hz) | 40mA: ±(1.0% +0.5mA) 400mA: ±(3.0% +5.0mA) 4A: ±(4.0% +0.1A) 40A: ±(4.0% +1.0A) 100A: ±(5.0% +1.0A) |
| Resolution | 10µA, 100µA, 1mA, 10mA, 100mA |
| Voltage | |
| Range | 400V |
| Accuracy (50-60Hz) | ±(1.5% +2 dgts.) |
| Resolution | 0.1V |
| Resistance | |
| Range | 40 to 400Ω |
| Accuracy | ±(1.0% +2 dgts.) |
| Resolution | 0.1Ω |
| General Specifications | |
| Range Selection | Manual |
| Sampling Time | Display: 2x / sec. Bargraph: 20x / sec. |
| Display | 4,000 count LCD display |
| Display Hold | Yes |
| Max/Min | Yes |
| Zero Push Button Adjustment | Yes |
| Relative Mode | Yes |
| Analog Bargraph | Yes (40 segment) |
| Continuity Check | Audible signal if resistance <40Ω |
| Auto Shut Off | Yes (after 30 minutes, off) |
| Power Supply | 9V Battery |
| Low Battery Indicator | Yes |
| Jaw Opening | 1.2" (30mm) |
| Overvoltage Category | CAT. II 600V |
| Operating Temperature | 14 to 122°F (-10 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Dimensions | 8.3 x 2.4 x 1.4" (210 x 62 x 36 mm) |
| Weight | 7.1 oz (200g) |
Click on a category to view a selection of compatible accessories with the REED ST-9809 AC Leakage Current Tester.