Simultaneously displaying the gas type, readings, and status for gas detection, this four-channel wall mount controller comes with a large strobe light and can monitor any combination of direct connect sensors as well as any 4 to 20 mA transmitter.
Simultaneously displaying the gas type, readings, and status for gas detection, this four-channel wall mount controller comes with a large strobe light and can monitor any combination of direct connect sensors as well as any 4 to 20 mA transmitter.
Capable of detecting gas at up to four locations, this four-channel wall mount controller has a built-in silenceable audible alarm that alerts you to alarm conditions.
Features
Applications
Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -4 to 158°F (-40 to 70°C) |
Enclosure Rating | NEMA 4X enclosure, chemical and weather resistant Suitable for indoor and outdoor installations |
Conduit Connection | ¾" (1.9 cm) NPT conduit hubs 4 provided: Sensor, power, and relay wiring |
Wiring Termination | Screw type terminal block, 14 gauge maximum |
Display | Four line OLED display |
Audible | Built-in audible alarm: 94 dB (mounted on enclosure) Coded output: pulsing = gas alarm, steady = fail |
Relays | Two flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any) Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel 10 A contact rating, 250 V |
Power | 115 V AC, 220 V AC, or 24 V DC nominal Battery backup option available |
Sampling Methods | Diffusion and sample draw heads available |
Approvals | CSA Certified to CSA C22.2 No. 61010-1-12 and UL61010-1 |
Dimensions | 12.5 x 11 x 6.4" (31.8 x 27.9 x 13.6 cm) |
Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -4 to 158°F (-40 to 70°C) |
Enclosure Rating | NEMA 4X enclosure, chemical and weather resistant Suitable for indoor and outdoor installations |
Conduit Connection | ¾" (1.9 cm) NPT conduit hubs 4 provided: Sensor, power, and relay wiring |
Wiring Termination | Screw type terminal block, 14 gauge maximum |
Display | Four line OLED display |
Audible | Built-in audible alarm: 94 dB (mounted on enclosure) Coded output: pulsing = gas alarm, steady = fail |
Relays | Two flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any) Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel 10 A contact rating, 250 V |
Power | 115 V AC, 220 V AC, or 24 V DC nominal Battery backup option available |
Sampling Methods | Diffusion and sample draw heads available |
Approvals | CSA Certified to CSA C22.2 No. 61010-1-12 and UL61010-1 |
Dimensions | 12.5 x 11 x 6.4" (31.8 x 27.9 x 13.6 cm) |