Sleek with a low-profile design, this 115 V AC indoor single-gas detector detects O2 with a 0 to 25% range and 0.1% increments. Users are notified by an audible alarm tone and multicolored LED display when abnormal oxygen levels are present. In addition, this detector comes with a power cord.
Sleek with a low-profile design, this 115 V AC indoor single-gas detector detects O2 with a 0 to 25% range and 0.1% increments. Users are notified by an audible alarm tone and multicolored LED display when abnormal oxygen levels are present. In addition, this detector comes with a power cord.
This long life sensor is field replaceable with no special tools required and can also be remotely mounted with an optional remote sensor cable.
Features
Applications
| Detection Principle | Galvanic cell |
| Gas Detected | Oxygen (O2) |
| Detection Range | 0 to 25 vol% |
| Display Resolution | 0.1 vol% |
| Sampling Method | Diffusion or remote sampling method with optional extender cable |
| Indication Accuracy | Within ±0.7 vol% |
| Response Time/td> | 90% response within 30 seconds |
| Alarm Delay Time | Within 5 seconds, after detecting 10 to 11 vol% gas at Oxygen deficiency alarm (18 vol% alarm) |
| Alarm Accuracy | Within ±1 vol% of preset alarms |
| Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.0% vol, alarm 2 = 18.0% vol (other settings available) |
| Display of Alarm | 1st gas alarm: gas concentration reading blinks or orange light, flashing AL1 light or orange light, buzzer 2nd gas alarm: gas concentration reading blinks or red light, flashing AL2 light or red light, buzzer |
| Alarm Method | Latching or non-latching |
| Display | Digital LCD (3 digits, 7 segments/Green, Orange, Red) |
| Dimensions | 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
| Weight | 7.05 oz (200 g) |
| Detection Principle | Galvanic cell |
| Gas Detected | Oxygen (O2) |
| Detection Range | 0 to 25 vol% |
| Display Resolution | 0.1 vol% |
| Sampling Method | Diffusion or remote sampling method with optional extender cable |
| Indication Accuracy | Within ±0.7 vol% |
| Response Time/td> | 90% response within 30 seconds |
| Alarm Delay Time | Within 5 seconds, after detecting 10 to 11 vol% gas at Oxygen deficiency alarm (18 vol% alarm) |
| Alarm Accuracy | Within ±1 vol% of preset alarms |
| Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.0% vol, alarm 2 = 18.0% vol (other settings available) |
| Display of Alarm | 1st gas alarm: gas concentration reading blinks or orange light, flashing AL1 light or orange light, buzzer 2nd gas alarm: gas concentration reading blinks or red light, flashing AL2 light or red light, buzzer |
| Alarm Method | Latching or non-latching |
| Display | Digital LCD (3 digits, 7 segments/Green, Orange, Red) |
| Dimensions | 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
| Weight | 7.05 oz (200 g) |