RKI S1A DIN Rail Mounting Smart LVDT Signal Conditioner

Model: S1A

RKI S1A DIN Rail Mounting Smart LVDT Signal Conditioner

Model: S1A

The signal conditioner features a smart setup with front panel buttons and LED indicators. It can be saved and reloaded via an RS-485 port.

The signal conditioner features a smart setup with front panel buttons and LED indicators. It can be saved and reloaded via an RS-485 port.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Electricity category for similar products.

Or let's do a search and help you find what you need:


RKI S1A Offers

The RKI S1A DIN Rail Mounting Smart LVDT Signal Conditioner ends the difficulties that accompany AC-LVDT setup with built-in null indicators and front panel push-buttons. It is engineered to work with the widest range of AC-LVDTs and inductive half-bridge LVRTs for your convenience. It offers a choice of 4 excitation frequencies and 8 analog outputs.

Features

  • Smart setup with front panel push-buttons so there's no need for pots or calculations
  • Built-in null indication with front panel LEDs and DC null voltage output
  • Auto-mastering provides fail-safe excitation syncing for multiple units
  • Self-diagnostics for LVDT failure or disconnect; open-collector output
  • Half-duplex digital communications via RS-485 2-wire multi-drop bus
  • Hot swapability allows setup to be saved and reloaded via RS-485 port

RKI S1A Specifications

Operating Power 15 to 30 V DC (24 V nominal), 60 mA max. at 24 V DC; 15 V DC and -15 V DC needed for ±10 V DC bipolar output
Excitation Voltage 3 Vrms (nominal) push-pull drive (factory default); 4.5 Vrms (nominal) push-pull drive (via jumper change); 1.5 Vrms (nom) single ended drive (for low impedance primary)
Excitation Frequencies 1 kHz, 3 kHz, 5 kHz, 10 kHz (nominal)
Auto-Master Syncing Master output couples up to 15 slave units; if master fails, new master is automatically generated for fail-safe excitation
LVDT AC Output Range 50 mVrms to 5,000 mVrms at LVDT i´s full scale position
Analog DC Output 0 to 5 V, 1 to 5 V, 0.5 to 4.5 V, 0.5 to 9.5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA sourcing, 4 to 20 mA sourcing
Loop Resistance 850 Ω max. with 24 V DC supply
Output Non-Linearity ± 0.025% of full span output (FSO)
Noise and Ripple ≤ 2.5 mVrms (voltage output); ≤ 5 µArms (current loop output)
Fault Detection Open LVDT winding, cable disconnected, loss of excitation
Failure Indication Flashing LEDs; analog output out of range; open-collector switch
Null Detection Front panel LEDs
Null Output Signal Up to ±3 V DC
Temperature Coefficient ± 0.002% of FSO/°C (combined zero and span shift)
Zero Set Front panel push-button or RS-485 command
Full Scale Set Front panel push-button or RS-485 command
Digital Interface RS-485 2-wire multi-drop network, 16 addresses
Additional Option USB to RS-485 cable at USD=60

What's included with the RKI S1A

  • Signal Conditioner
  • Plug-In Screw Terminal Connectors
  • Two-Year Warranty

Ask a question about RKI S1A DIN Rail Mounting Smart LVDT Signal Conditioner

Customer Reviews for the RKI S1A

RKI S1A Offers

The RKI S1A DIN Rail Mounting Smart LVDT Signal Conditioner ends the difficulties that accompany AC-LVDT setup with built-in null indicators and front panel push-buttons. It is engineered to work with the widest range of AC-LVDTs and inductive half-bridge LVRTs for your convenience. It offers a choice of 4 excitation frequencies and 8 analog outputs.

Features

  • Smart setup with front panel push-buttons so there's no need for pots or calculations
  • Built-in null indication with front panel LEDs and DC null voltage output
  • Auto-mastering provides fail-safe excitation syncing for multiple units
  • Self-diagnostics for LVDT failure or disconnect; open-collector output
  • Half-duplex digital communications via RS-485 2-wire multi-drop bus
  • Hot swapability allows setup to be saved and reloaded via RS-485 port

RKI S1A Specifications

Operating Power 15 to 30 V DC (24 V nominal), 60 mA max. at 24 V DC; 15 V DC and -15 V DC needed for ±10 V DC bipolar output
Excitation Voltage 3 Vrms (nominal) push-pull drive (factory default); 4.5 Vrms (nominal) push-pull drive (via jumper change); 1.5 Vrms (nom) single ended drive (for low impedance primary)
Excitation Frequencies 1 kHz, 3 kHz, 5 kHz, 10 kHz (nominal)
Auto-Master Syncing Master output couples up to 15 slave units; if master fails, new master is automatically generated for fail-safe excitation
LVDT AC Output Range 50 mVrms to 5,000 mVrms at LVDT i´s full scale position
Analog DC Output 0 to 5 V, 1 to 5 V, 0.5 to 4.5 V, 0.5 to 9.5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA sourcing, 4 to 20 mA sourcing
Loop Resistance 850 Ω max. with 24 V DC supply
Output Non-Linearity ± 0.025% of full span output (FSO)
Noise and Ripple ≤ 2.5 mVrms (voltage output); ≤ 5 µArms (current loop output)
Fault Detection Open LVDT winding, cable disconnected, loss of excitation
Failure Indication Flashing LEDs; analog output out of range; open-collector switch
Null Detection Front panel LEDs
Null Output Signal Up to ±3 V DC
Temperature Coefficient ± 0.002% of FSO/°C (combined zero and span shift)
Zero Set Front panel push-button or RS-485 command
Full Scale Set Front panel push-button or RS-485 command
Digital Interface RS-485 2-wire multi-drop network, 16 addresses
Additional Option USB to RS-485 cable at USD=60

What's included with the RKI S1A

  • Signal Conditioner
  • Plug-In Screw Terminal Connectors
  • Two-Year Warranty

Ask a question about RKI S1A DIN Rail Mounting Smart LVDT Signal Conditioner

Customer Reviews for the RKI S1A

More RKI Products