Effortlessly monitor indoor air quality with this CO2 display that can be wall-mounted or placed on a surface. With a large and easy-to-read display and large buttons for easy operation, measured values can be recorded, stored, and exported to a USB stick.
Effortlessly monitor indoor air quality with this CO2 display that can be wall-mounted or placed on a surface. With a large and easy-to-read display and large buttons for easy operation, measured values can be recorded, stored, and exported to a USB stick.
Minimize the risk of infection with viruses or bacteria and increase well-being and concentration by monitoring indoor air parameters.
Features
Applications
| CO2 Measurement | |
| Measurement Principle | Infrared (NDIR) with automatic calibration (ABC) |
| Measuring Range | 0 to 9999 ppm |
| Accuracy at 23°C ±5 K | ±30 ppm ±5 % of the measured value at 0 to 5000 ppm |
| Resolution | 1 ppm |
| Adjustment Point | 400 ppm |
| Pressure Dependence | +1.6 % reading per kPa |
| Null Drift | <10 ppm/year |
| Maintenance | No maintenance (standard indoor applications) |
| Humidity Measurement | |
| Humidity Sensor | ROTRONIC HYGROMER® IN-1 |
| Measuring Range | 0 to 100% RH |
| Accuracy at 23°C ±5 K | ±2% RH (10 to 90% RH), others ±5% RH |
| Resolution | 0.1% RH |
| Adjustment Points | 35, 80% RH |
| Response Time 63 | <30 s, without filter |
| Long-Term Stability | <1.5% RH/year |
| Temperature Measurement | |
| Sensor | NTC thermistor |
| Measuring Range | -20 to 60°C |
| Accuracy at 23°C ±5 K | ±0.3 K |
| Resolution | 0.1°C |
| Response Time | 4 s |
| General Specifications | |
| Current Consumption | 700 mA |
| Warm-up Time | <1 minute |
| Memory Capacity | 19,500 values with time stamp Automatic recording (%RH/°C/ppm) |
| Type | Wall or benchtop display unit |
| Parameters | CO2, relative humidity and temperature |
| Application Range | 0 to 50°C/0 to 95% RH, non-condensing |
| Clock | Real time clock with 4 min. battery backup |
| Alarm/Indicator | Adjustable for CO2 measurement (visual) |
| Dimensions | 11.8 x 9.8 x 1.9" (330 x 250 x 50 mm) |
| Weight | 3 lbs (1400 g) |
| CO2 Measurement | |
| Measurement Principle | Infrared (NDIR) with automatic calibration (ABC) |
| Measuring Range | 0 to 9999 ppm |
| Accuracy at 23°C ±5 K | ±30 ppm ±5 % of the measured value at 0 to 5000 ppm |
| Resolution | 1 ppm |
| Adjustment Point | 400 ppm |
| Pressure Dependence | +1.6 % reading per kPa |
| Null Drift | <10 ppm/year |
| Maintenance | No maintenance (standard indoor applications) |
| Humidity Measurement | |
| Humidity Sensor | ROTRONIC HYGROMER® IN-1 |
| Measuring Range | 0 to 100% RH |
| Accuracy at 23°C ±5 K | ±2% RH (10 to 90% RH), others ±5% RH |
| Resolution | 0.1% RH |
| Adjustment Points | 35, 80% RH |
| Response Time 63 | <30 s, without filter |
| Long-Term Stability | <1.5% RH/year |
| Temperature Measurement | |
| Sensor | NTC thermistor |
| Measuring Range | -20 to 60°C |
| Accuracy at 23°C ±5 K | ±0.3 K |
| Resolution | 0.1°C |
| Response Time | 4 s |
| General Specifications | |
| Current Consumption | 700 mA |
| Warm-up Time | <1 minute |
| Memory Capacity | 19,500 values with time stamp Automatic recording (%RH/°C/ppm) |
| Type | Wall or benchtop display unit |
| Parameters | CO2, relative humidity and temperature |
| Application Range | 0 to 50°C/0 to 95% RH, non-condensing |
| Clock | Real time clock with 4 min. battery backup |
| Alarm/Indicator | Adjustable for CO2 measurement (visual) |
| Dimensions | 11.8 x 9.8 x 1.9" (330 x 250 x 50 mm) |
| Weight | 3 lbs (1400 g) |