Sauermann Si-RD3 Refrigerant Leak Detector

Model: 27867

Sauermann Si-RD3 Refrigerant Leak Detector

Model: 27867

This refrigerant leak detector is capable of detecting the most common refrigerants, including all HCFCs and HFCs such as R1234ze, R290, and R600a. It has a high sensitivity of 0 to 3 g/year and features a heated diode sensor, visible and audible alarms, manual and automatic autozero, a flexible probe, and three modes of sensitivity: Low, Normal, and High.

This refrigerant leak detector is capable of detecting the most common refrigerants, including all HCFCs and HFCs such as R1234ze, R290, and R600a. It has a high sensitivity of 0 to 3 g/year and features a heated diode sensor, visible and audible alarms, manual and automatic autozero, a flexible probe, and three modes of sensitivity: Low, Normal, and High.

Sale Price $407.11 USD
Regular Price $508.89 USD
Availability 2 to 3 Weeks
Quantity

Sauermann 27867 Offers

The Sauermann Si-RD3 is a refrigerant leak detector for the most common refrigerants, including all HCFC and HFC R1234ze, R290, R600a, and 5% hydrogen-95% nitrogen mixtures (Nidron and Trace-A-Gas. ) The refrigerant gas leak detector has a high sensitivity of 0-3 g/year. The Si-RD3 refrigerant leak detector features a Heated diode sensor, visible and audible alarms, manual and automatic autozero, and a flexible 11. 81 probe, and 3 modes of sensitivity: Low, Normal, and High.

This lightweight, easy-to-hold, handheld refrigerant leak detector is crucial for HVAC/R technicians monitoring the integrity of refrigeration systems in a variety of environments, from supermarkets to industrial plants.

Features

  • Detection includes: all HFCF and HFC refrigerants, R1234yf, R1234ze, R290, R600a, and 5% hydrogen - 95% nitrogen mixtures (Nidron 5, Trace-A-Gas)
  • Manual and automatic autozero
  • Immediately ready to use with no presets
  • Heated diode sensor
  • 3 modes: Low, Normal and High sensitivity
  • Detects most common refrigerants and mixtures
  • Highly sensitive: 0 to 3 g/year
  • Minimum threshold of sensitivity
  • Fixed: < 1 g/year at 3 mm
  • In moving air: 2 g/year, 2 cm/s at 3 mm
  • Minimum time of detection (1 g/year): 1 second
  • Autozero: 2 seconds
  • Recuperation time after exposition: from 1 to 10 seconds (depending on detection level and threshold of sensitivity)
  • Visible and audible alarms
  • 30 cm flexible probe
  • IP54

Applications

  • HVAC/R technicians

Sauermann 27867 Specifications

Main Detected Refrigerants HFC: R134a, R404a, R407c, R410a, R32, R422a/b/c/d, R425a, R507a, R125
HCFC: R22
CFC: R12, R502
Others: 5% hydrogen - 95% nitrogen (Nidron 5, Trace-A-Gas), R290, R600a, R1234yf, R1234ze
Measuring Element Semiconductor sensor
Display 13 LEDs:
8 for the graphic visualization of thresholds
3 for the sensitivity of detection
2 for the battery level and manual autozero
Indication LED: gradual lighting up when the gas concentration increases
Audible: the beep frequency increases when the gas concentration increases
Probe Flexible, 11.8" length (300 mm)
Autonomy > 12 hours
Housing ABS topsafe, protection IP54
Keypad 3 keys
European Directives 2014/30/EU EMC
2014/35/EU Low Voltage
RoHS 2011/65/EU (EU)2015/863
2012/19/EU WEEE
Power Supply 4 AAA LR03 1.5 V batteries
Ambiance Air and non-corrosive gases
Conditions Of Use (°f, %rh, Ft) From 32 to 122 °F (0 to +50 °C). In non-condensing conditions.
From 0 to 6562' (0 to 2000 m)
Storage Temperature From -4 to 176 °F (-20 to +80 °C)
Auto-extinction 15 minutes
Weight 10.4 oz (295 g)

What's included with the Sauermann 27867

  • Sauermann Si-RD3 Refrigerant Gas Detector
  • Filter
  • Carrying bag
  • Verification certificate
  • Quick Start Guide

Ask a question about Sauermann Si-RD3 Refrigerant Leak Detector

Customer Reviews for the Sauermann 27867

Sauermann 27867 Offers

The Sauermann Si-RD3 is a refrigerant leak detector for the most common refrigerants, including all HCFC and HFC R1234ze, R290, R600a, and 5% hydrogen-95% nitrogen mixtures (Nidron and Trace-A-Gas. ) The refrigerant gas leak detector has a high sensitivity of 0-3 g/year. The Si-RD3 refrigerant leak detector features a Heated diode sensor, visible and audible alarms, manual and automatic autozero, and a flexible 11. 81 probe, and 3 modes of sensitivity: Low, Normal, and High.

This lightweight, easy-to-hold, handheld refrigerant leak detector is crucial for HVAC/R technicians monitoring the integrity of refrigeration systems in a variety of environments, from supermarkets to industrial plants.

Features

  • Detection includes: all HFCF and HFC refrigerants, R1234yf, R1234ze, R290, R600a, and 5% hydrogen - 95% nitrogen mixtures (Nidron 5, Trace-A-Gas)
  • Manual and automatic autozero
  • Immediately ready to use with no presets
  • Heated diode sensor
  • 3 modes: Low, Normal and High sensitivity
  • Detects most common refrigerants and mixtures
  • Highly sensitive: 0 to 3 g/year
  • Minimum threshold of sensitivity
  • Fixed: < 1 g/year at 3 mm
  • In moving air: 2 g/year, 2 cm/s at 3 mm
  • Minimum time of detection (1 g/year): 1 second
  • Autozero: 2 seconds
  • Recuperation time after exposition: from 1 to 10 seconds (depending on detection level and threshold of sensitivity)
  • Visible and audible alarms
  • 30 cm flexible probe
  • IP54

Applications

  • HVAC/R technicians

Sauermann 27867 Specifications

Main Detected Refrigerants HFC: R134a, R404a, R407c, R410a, R32, R422a/b/c/d, R425a, R507a, R125
HCFC: R22
CFC: R12, R502
Others: 5% hydrogen - 95% nitrogen (Nidron 5, Trace-A-Gas), R290, R600a, R1234yf, R1234ze
Measuring Element Semiconductor sensor
Display 13 LEDs:
8 for the graphic visualization of thresholds
3 for the sensitivity of detection
2 for the battery level and manual autozero
Indication LED: gradual lighting up when the gas concentration increases
Audible: the beep frequency increases when the gas concentration increases
Probe Flexible, 11.8" length (300 mm)
Autonomy > 12 hours
Housing ABS topsafe, protection IP54
Keypad 3 keys
European Directives 2014/30/EU EMC
2014/35/EU Low Voltage
RoHS 2011/65/EU (EU)2015/863
2012/19/EU WEEE
Power Supply 4 AAA LR03 1.5 V batteries
Ambiance Air and non-corrosive gases
Conditions Of Use (°f, %rh, Ft) From 32 to 122 °F (0 to +50 °C). In non-condensing conditions.
From 0 to 6562' (0 to 2000 m)
Storage Temperature From -4 to 176 °F (-20 to +80 °C)
Auto-extinction 15 minutes
Weight 10.4 oz (295 g)

What's included with the Sauermann 27867

  • Sauermann Si-RD3 Refrigerant Gas Detector
  • Filter
  • Carrying bag
  • Verification certificate
  • Quick Start Guide

Ask a question about Sauermann Si-RD3 Refrigerant Leak Detector