The Softing WX4500-FA WireXpert Advanced LAN Certifier Kit for Copper Cables is a state-of-the-art certifying instrument for Copper LAN cabling that is capable of the highest level cable certifications in enterprise networks and data centers with testing up to Class FA and new CAT8 copper , as well as optional upgrades for MPO, SM and MM fiber optic.
The Softing WX4500-FA WireXpert Advanced LAN Certifier Kit for Copper Cables is a state-of-the-art certifying instrument for Copper LAN cabling that is capable of the highest level cable certifications in enterprise networks and data centers with testing up to Class FA and new CAT8 copper , as well as optional upgrades for MPO, SM and MM fiber optic.
The Softing WX4500-FA WireXpert performs the most complex testing protocols quickly and accurately and can provide pass/fail results in a matter of seconds, with access to detailed test records for every available certification standard.
Features
Applications
Certification Testing | TIA 568-C.2 CAT 5e, 6, 6A, draft CAT 8ISO/IEC 11801, EN 50173 Class D,E,EA,F,FA draft Class I and Class II Permanent link and channel CAT 5e, 6, 6A, 7, 7A and patch-cord |
Autotest Time - CAT6A | 9 sec |
Autotest time - Class FA | 15 sec |
Max Cable Length for dual ended Autotest | 500m |
Insertion Cycles | Channel: 10,000 typical
Permanent Link: 5,000 typical |
Test Parameters | As specified in TIA 1152, IEC 61935-1; including Wiremap |
Loop Resistance | 0 to 40 ohm, ±0.1 ohm |
Length | 0 to 500m, ±0.5m (dual ended testing) |
Propagation Delay and Delay Skew | 0 to 5000 ns, ±1 ns |
Attenuation | 0 to 70 dB, ±0.1dB |
Pair-to-Pair and Power-Sum NEXT | 0 to 85 dB, ±0.2 dB |
Pair-to-Pair and Power-Sum ACRF | 0 to 85 dB, ±0.2 dB |
Return Loss | 0 to 40 dB, ±0.2 dB |
ACRN, PSACRN | -25 to 85 dB, ±0.5 dB |
Advanced Diagnostics | Time-domain fault Locator for RL and NEXT |
Measurement Accuracy | Exceeds TIA 1152 Level IIIe, IEC 61935 level IV |
Measurement Frequency Range | 1-2, 500 MHz |
Certification Testing | TIA 568-C.2 CAT 5e, 6, 6A, draft CAT 8ISO/IEC 11801, EN 50173 Class D,E,EA,F,FA draft Class I and Class II Permanent link and channel CAT 5e, 6, 6A, 7, 7A and patch-cord |
Autotest Time - CAT6A | 9 sec |
Autotest time - Class FA | 15 sec |
Max Cable Length for dual ended Autotest | 500m |
Insertion Cycles | Channel: 10,000 typical
Permanent Link: 5,000 typical |
Test Parameters | As specified in TIA 1152, IEC 61935-1; including Wiremap |
Loop Resistance | 0 to 40 ohm, ±0.1 ohm |
Length | 0 to 500m, ±0.5m (dual ended testing) |
Propagation Delay and Delay Skew | 0 to 5000 ns, ±1 ns |
Attenuation | 0 to 70 dB, ±0.1dB |
Pair-to-Pair and Power-Sum NEXT | 0 to 85 dB, ±0.2 dB |
Pair-to-Pair and Power-Sum ACRF | 0 to 85 dB, ±0.2 dB |
Return Loss | 0 to 40 dB, ±0.2 dB |
ACRN, PSACRN | -25 to 85 dB, ±0.5 dB |
Advanced Diagnostics | Time-domain fault Locator for RL and NEXT |
Measurement Accuracy | Exceeds TIA 1152 Level IIIe, IEC 61935 level IV |
Measurement Frequency Range | 1-2, 500 MHz |