Simple, robust, and reliable, this 3" (76.2 mm) cone meter is ideal for reading liquid, steam, and gas in rugged conditions where accuracy, low maintenance, and cost are crucial. In addition, this meter features a DP built-in flow conditioning design, a pressure rating of 150#, and a carbon steel body.
Simple, robust, and reliable, this 3" (76.2 mm) cone meter is ideal for reading liquid, steam, and gas in rugged conditions where accuracy, low maintenance, and cost are crucial. In addition, this meter features a DP built-in flow conditioning design, a pressure rating of 150#, and a carbon steel body.
Capable of reading flow rates using differential pressure or multi-variable transmitters in conjunction with a flow computer, this cone meter measures differential pressure through an integrated electronic signal, typically via standard Modbus or 4 to 20mA output. Especially useful in tight-fit and retrofit installations where the long runs of straight pipe required by orifice plates, venturi tubes, and other technologies are impractical or unavailable, this versatile cone meter is installable in a horizontal or vertical position.
Features
Applications
Pressure | Rating: 150# Taps size: ½" Tap style: 3000 psi NPT |
Accuracy | ±0.5% with calibration |
Repeatability | ±0.1% or better |
Flow Ranges | 10:1 and greater |
Meter Body | Carbon steel (standard) |
Pipe Schedule | Standard |
Process Connection | Raised-face slip-on |
Cone | Type: Fixed cone Material: 316L SS |
Tap Location | Cone taps |
Beta | Special |
Calibration | Dry (ISO 1567) |
Size | 3" (76.2 mm) |
Pressure | Rating: 150# Taps size: ½" Tap style: 3000 psi NPT |
Accuracy | ±0.5% with calibration |
Repeatability | ±0.1% or better |
Flow Ranges | 10:1 and greater |
Meter Body | Carbon steel (standard) |
Pipe Schedule | Standard |
Process Connection | Raised-face slip-on |
Cone | Type: Fixed cone Material: 316L SS |
Tap Location | Cone taps |
Beta | Special |
Calibration | Dry (ISO 1567) |
Size | 3" (76.2 mm) |