Featuring a user-friendly interface and excellent performance, the programmable DC electronic load has an input range of 150 V/30 A 200 W. With clear visuals on the 3.5" TFT-LCD, it is an absolute must for any manufacturer to test their sources.
Featuring a user-friendly interface and excellent performance, the programmable DC electronic load has an input range of 150 V/30 A 200 W. With clear visuals on the 3.5" TFT-LCD, it is an absolute must for any manufacturer to test their sources.
A steady state operating mode and dynamic test mode up to 25 kHz. the unit provides flexible testing capabilities and can switch between two different load values.
Features
| Input Rating (0 to 104°F/0 to 40°C) | ||
| Input Voltage | 0 to 150 V | |
| Input Current | 0 to 5 A 0 to 30 A |
|
| Input Power | 200 W | |
| Minimum Operating Voltage (DC) | 0.15 V at 5 A 0.9 V at 30 A |
|
| CV Mode | ||
| Range | 0 to 36 V 0 to 150 V |
|
| Resolution | 1 mV | |
| Accuracy | ±(0.05% + 0.025% FS) 50 ppm/C° | |
| CC Mode | ||
| Range | 0 to 5 A | 0 to 30 A |
| Resolution | 1 mA | |
| Accuracy2 | ±(0.1% + 0.1%FS) 100 ppm/°C | |
| CR Mode1 | ||
| Range | 0.03 Ω to 10 kΩ | |
| Resolution | 1 mA/V sense | |
| Accuracy | 0.01% + 0.0008 s [1] | |
| CP Mode3 | ||
| Range | 200 W | |
| Resolution | 10 mW | |
| Accuracy | 0.1% + 0.1% FS | |
| Dynamic Model - CC Mode | ||
| T1 and T2 | 20 us to 999 S/Res: 1 uS | |
| Accuracy | 20 us to 200 ms/Acc: 5 us, 200 ms to 999 s/Acc: 5 ms | |
| Current Slew Rate4 | 0.001 to 0.5 A/us | 0.001 to 2.5 A/us |
| Minimum Rise Time | ≈10 uS ≈12 uS |
|
| Measuring Range | ||
| Readback Voltage | Range: 0 to 36 V, 0 to 150 V Resolution: 1 mV, 1 mV Accuracy: ± (0.05% + 0.02% FS) 20 ppm/°C |
|
| Readback Current | Range: 0 to 5 A, 0 to 30 A Resolution: 1 mA Accuracy: ±(0.05% + 0.05% FS) 50 ppm/°C |
|
| Readback Power | Range: 200 W Resolution: 10 mW Acuracy: ±(0.1% + 0.1% FS) |
|
| Readback Resistance | Range: 0.03 Ω to 10 KΩ Resolution: 0.001 Ω |
|
| CR Mode | ||
| I Range | 5 A, 30 A | |
| V Range | 36 V, 150 V, 36 V, 150 V | |
| R Range | 0.03 Ω to 10 kΩ | |
| Accuracy | 0.01% + 0.08 s (0.05 to 10 Ω) 0.01% + 0.0008 s (10~10000 Ω)[1] |
|
| Test Condition | The input voltage/current value should not be smaller than 10% of the full scale | |
| Protection Range | ||
| OPP: 210 W OCP: 5.1 A, 31 A OVP: 41 V. 155 V OTP: 85°C |
||
| Battery Measurement | Battery input: 0.5 to 150 V Maximum measurement: capacity=999 AH Resolution=0.1 mA; time range=1 s to 24 H |
|
| Input Resistance | >200 kΩ | |
| Dimensions | 10 x 4.52 x 16" (256 x 115 x 410 mm) | |
| Weight | 12.7 lbs (5.8 kg) | |
| [1] Resistance Range: (1/(1/R+(1/R)*0.01%+0.0008),1/(1/R-(1/R)*0.01%-0.0008) 2Current Slew rate>0.2 A/us 3The input voltage/current value should not be smaller than 10% of the full scale 4Current slew rate: rising slew rate for 10%~90% of the current (0-maximum current) |
||
| Input Rating (0 to 104°F/0 to 40°C) | ||
| Input Voltage | 0 to 150 V | |
| Input Current | 0 to 5 A 0 to 30 A |
|
| Input Power | 200 W | |
| Minimum Operating Voltage (DC) | 0.15 V at 5 A 0.9 V at 30 A |
|
| CV Mode | ||
| Range | 0 to 36 V 0 to 150 V |
|
| Resolution | 1 mV | |
| Accuracy | ±(0.05% + 0.025% FS) 50 ppm/C° | |
| CC Mode | ||
| Range | 0 to 5 A | 0 to 30 A |
| Resolution | 1 mA | |
| Accuracy2 | ±(0.1% + 0.1%FS) 100 ppm/°C | |
| CR Mode1 | ||
| Range | 0.03 Ω to 10 kΩ | |
| Resolution | 1 mA/V sense | |
| Accuracy | 0.01% + 0.0008 s [1] | |
| CP Mode3 | ||
| Range | 200 W | |
| Resolution | 10 mW | |
| Accuracy | 0.1% + 0.1% FS | |
| Dynamic Model - CC Mode | ||
| T1 and T2 | 20 us to 999 S/Res: 1 uS | |
| Accuracy | 20 us to 200 ms/Acc: 5 us, 200 ms to 999 s/Acc: 5 ms | |
| Current Slew Rate4 | 0.001 to 0.5 A/us | 0.001 to 2.5 A/us |
| Minimum Rise Time | ≈10 uS ≈12 uS |
|
| Measuring Range | ||
| Readback Voltage | Range: 0 to 36 V, 0 to 150 V Resolution: 1 mV, 1 mV Accuracy: ± (0.05% + 0.02% FS) 20 ppm/°C |
|
| Readback Current | Range: 0 to 5 A, 0 to 30 A Resolution: 1 mA Accuracy: ±(0.05% + 0.05% FS) 50 ppm/°C |
|
| Readback Power | Range: 200 W Resolution: 10 mW Acuracy: ±(0.1% + 0.1% FS) |
|
| Readback Resistance | Range: 0.03 Ω to 10 KΩ Resolution: 0.001 Ω |
|
| CR Mode | ||
| I Range | 5 A, 30 A | |
| V Range | 36 V, 150 V, 36 V, 150 V | |
| R Range | 0.03 Ω to 10 kΩ | |
| Accuracy | 0.01% + 0.08 s (0.05 to 10 Ω) 0.01% + 0.0008 s (10~10000 Ω)[1] |
|
| Test Condition | The input voltage/current value should not be smaller than 10% of the full scale | |
| Protection Range | ||
| OPP: 210 W OCP: 5.1 A, 31 A OVP: 41 V. 155 V OTP: 85°C |
||
| Battery Measurement | Battery input: 0.5 to 150 V Maximum measurement: capacity=999 AH Resolution=0.1 mA; time range=1 s to 24 H |
|
| Input Resistance | >200 kΩ | |
| Dimensions | 10 x 4.52 x 16" (256 x 115 x 410 mm) | |
| Weight | 12.7 lbs (5.8 kg) | |
| [1] Resistance Range: (1/(1/R+(1/R)*0.01%+0.0008),1/(1/R-(1/R)*0.01%-0.0008) 2Current Slew rate>0.2 A/us 3The input voltage/current value should not be smaller than 10% of the full scale 4Current slew rate: rising slew rate for 10%~90% of the current (0-maximum current) |
||