Teledyne LeCroy HVD3102 25 MHz High Voltage Differential Probe

Model: HVD3102

Teledyne LeCroy HVD3102 25 MHz High Voltage Differential Probe

Model: HVD3102

High voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments.

High voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Teledyne Lecroy 25 MHz High Voltage Differential Probe

The HVD3000 high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe's design is easy-to-use and enables safe, precise high voltage floating measurements.

Features

  • Differential voltage measurement capability up to 1000 Vrms
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • Wide differential voltage range of 1500 Vp-p, 2000 Vp-p before saturation for capture of short duration overshoots
  • High offset capability at both high and low attenuation
  • 1% DC and low frequency gain accuracy
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities

Specifications

  • Bandwidth: 25 MHz
  • Rise Time (10-90): 14 ns
  • High Attenuation Differential Voltage Range: 1500 V (DC + peak AC) from 7 to 400 V/div with up to 1500 V offset. 2000 V maximum typical measurable differential voltage before saturation.
  • Low Attenuation Differential Voltage Range: 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150 V offset.
  • Common Mode Voltage Range: ±1500 V (DC + peak AC), 1000 Vrms (CAT III) (either input to ground)
  • Maximum Input Voltage to Earth: 1000 Vrms (CAT III) (either input to ground)
  • Max Safe Input: 1000 Vrms CAT III
  • Sensitivity: 100 mV/div to 6.9V/div (100X); 7V/div to 400V/div (1000X)
  • Gain Accuracy: 1% (LF, guaranteed)
  • Slew Rate: 100 V/ns (maximum)
  • Attenuation: 100x / 1000x
  • Input Impedance: 10 MΩ || 2.5 pF (between inputs), 5 MΩ || 5.0 pF (either input to ground)
  • Input Coupling: DC only
  • Output Coupling: DC
  • Output Termination: 1 MΩ
  • Interface: ProBus
  • Cable Length: 2.25 m (overall from tip connection to oscilloscope connection), 40 cm input lead length

What's included with the Teledyne LeCroy HVD3102

  • Teledyne LeCroy HVD3102 25 MHz High Voltage Differential Probe

Ask a question about Teledyne LeCroy HVD3102 25 MHz High Voltage Differential Probe

Customer Reviews for the Teledyne LeCroy HVD3102

Teledyne Lecroy 25 MHz High Voltage Differential Probe

The HVD3000 high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe's design is easy-to-use and enables safe, precise high voltage floating measurements.

Features

  • Differential voltage measurement capability up to 1000 Vrms
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • Wide differential voltage range of 1500 Vp-p, 2000 Vp-p before saturation for capture of short duration overshoots
  • High offset capability at both high and low attenuation
  • 1% DC and low frequency gain accuracy
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities

Specifications

  • Bandwidth: 25 MHz
  • Rise Time (10-90): 14 ns
  • High Attenuation Differential Voltage Range: 1500 V (DC + peak AC) from 7 to 400 V/div with up to 1500 V offset. 2000 V maximum typical measurable differential voltage before saturation.
  • Low Attenuation Differential Voltage Range: 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150 V offset.
  • Common Mode Voltage Range: ±1500 V (DC + peak AC), 1000 Vrms (CAT III) (either input to ground)
  • Maximum Input Voltage to Earth: 1000 Vrms (CAT III) (either input to ground)
  • Max Safe Input: 1000 Vrms CAT III
  • Sensitivity: 100 mV/div to 6.9V/div (100X); 7V/div to 400V/div (1000X)
  • Gain Accuracy: 1% (LF, guaranteed)
  • Slew Rate: 100 V/ns (maximum)
  • Attenuation: 100x / 1000x
  • Input Impedance: 10 MΩ || 2.5 pF (between inputs), 5 MΩ || 5.0 pF (either input to ground)
  • Input Coupling: DC only
  • Output Coupling: DC
  • Output Termination: 1 MΩ
  • Interface: ProBus
  • Cable Length: 2.25 m (overall from tip connection to oscilloscope connection), 40 cm input lead length

What's included with the Teledyne LeCroy HVD3102

  • Teledyne LeCroy HVD3102 25 MHz High Voltage Differential Probe

Ask a question about Teledyne LeCroy HVD3102 25 MHz High Voltage Differential Probe

Customer Reviews for the Teledyne LeCroy HVD3102

More Teledyne LeCroy Products