A Two-Way Optical Loss Tester (OLTS) that's perfect for medium to ultra-high fiber count loss, length, and optical return loss testing applications on multimode fiber at 850 and 1330 nm. A pair of these compact instruments set new standards of productivity, accuracy, and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.

A Two-Way Optical Loss Tester (OLTS) that's perfect for medium to ultra-high fiber count loss, length, and optical return loss testing applications on multimode fiber at 850 and 1330 nm. A pair of these compact instruments set new standards of productivity, accuracy, and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.

Your Price $4752.36 USD
Availability 2 to 3 Weeks
Quantity

Tempo Communications T23403OLV-APC-50U Offers

The 650 nm VFL VisiTester feature mixes a VFL in with the test signal during Autotest. It operates as a stand-alone VFL or gives positive visual identification of a fiber to be connected during loss testing.

Each fiber needs just one test hook-up and one key press for a complete 2 W and bidirectional loss, length, and ORL test, and the same test method can be used for all fibers in a network, eliminating administration, training, and test errors. Testing is accurate and can take only 5 seconds, directly onto flexible standards-compliant Tier 1 certification reports.

A pair of instruments both display length and bi-directional loss, and ORL each end, in real time, with no need to specify master/slave instruments. A single instrument can also be used as a stand-alone ultra-stable light source and power meter, VFL, ORL meter, or tone generator/detector. The ORL meter is calibrated with 50 u fiber, and works on 62.5u fiber with an appropriate dB offset.

Features

  • 25% of the size and weight, 7x the battery life of competitors
  • Bidirectional Autotest loss, length and ORL testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass and Fail display
  • 8000 fiber memory and USB Flash Drive file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1% accuracy
  • Traceable calibration reports: Power meter and linearity, source λ and stability, ORL
  • 80 hours alkaline battery life
  • 3 Year warranty and calibration cycle
  • EF compliant multimode sources

Tempo Communications T23403OLV-APC-50U Specifications

Source
Modulated Output 270 Hz, 1 kHz, 2 kHz ±2%, 12 Multi-Fiber ID tones
Output Wavelength 850 and 1300 nm LED APC
VisiTester
Output Power -27 dBm ±1 dB at 62.5 μm
Adjust Output Power Fixed
Short Term Stability For 15 minutes
  • Typical ±2°C
    After warm up
    ORL < -25 dB
    • 0.01 dB
Stability Over Temperature 0.35 dB
Wavelength Drift Typical 0.4 nm per °C
Reconnection Repeatability 0.05 dB at 95% Confidence
Mode Controlled 50/125μm compliant:
  • IEC 61280-4-1 {Ed.1.0}
  • TIA 526-14A
  • TIA TSB-178
2-way Autotest Only
Length Range 4.5 dB at 50 μm
Length Accuracy 0.01% ± 4 meters
Length Resolutions 1 m (0.000 to 9.999 Km)
10 m (10.00 to 99.99 Km)
100 m (100.0 to 127.9 Km)
2-way Autotest
Loss Range 21.5 dB at 50 μm
Loss Repeatability and Loss Linearity 0.06 dB
1-way Autotest
Loss Range 21.5 at 50 μm
Loss Repeatability and Loss Linearity 0.06 dB
Meter
Detector Type InGaAs
Response Wavelength 600 and 1700 nm
Calibration Wavelengths 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
Accuracy 1% (0.06 dB)
Mid-range Linearity 0.04 dB (typical)
Power Range 10 to -60 dBm (780 and 980, and 1590 and 1650 nm)
10 to -70 dBm (1270 and 1650 nm)
Total Uncertainty 0.3 dB maximum
Resolution 0.01 dB
Polarization Sensitivity < 0.05 dB typical
ID Tone Detection and Autotest Sensitivity Up to -50 dBm
Tone Detection 150 to 9999 Hz ±1%
Orl Range 0 to 27.5 dB at 50 μm
Orl Port Isolation > 25 dB
Orl Accuracy 0.2 dB
Orl Resolution 0.01 dB (at 0 to 30 dB)
0.1 dB (at 30 to 45 dB)
VisiTester Wavelength 650 ±5 nm
VisiTester Power 0 dBm ±1 dB at SMF
VisiTester Laser Safety Class 1
IEC60825-2
VisiTester Blink Rate - Manual CW or 2 Hz
Autotest 1-way: Compatible with other T23400 and T27400 models
2-way: Compatible with identical model only
Usb Interfaces Micro-USB for power and software
USB-A Flash Drive
Software KITS - free download
Power Battery
External power via micro-USB
Battery Life Laser and LED source: Typically 80 hours in autotest
Power meter: Typically 1000 hours
Battery Type 2x AA (LR6) Alkaline
2x AA NiMH AA (rechargeable via micro-USB)
Auto Off Selectable
Display 2.9 x 2.2" (74 x 55 mm) high contrast LCD
Case Polycarbonate body
Rubber edges and corners
Moisture resistance
1 m drop tested
Memory For 8000 fibers
Unlimited on USB Flash Drive
Temperature Operating temperature: 5 to 131°F (-15 to 55°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Relative Humidity 0 to 95%
Calibration Validity ISO/IEC 17025 3 years
Warranty 3 years
Dimensions 7.4 x 4.1 x 1.4" (190 x 105 x 35 mm)
Weight 0.93 lbs (0.42 kg)
Shipping Weight 3.3 lbs (1.5 kg)

What's included with the Tempo Communications T23403OLV-APC-50U

  • Tempo T23403OLV-APC-50U Ultra-Stable 2 W Loss Length ORL Tester with 850 - 1330 nm port, and InGaAs detector type
  • Three-Years Warranty

Ask a question about Tempo T23403OLV-APC-50U Ultra-Stable 2 W Loss Length ORL Tester Calibrated for 50 um with VisiTester, 850 and 1330 nm port

Customer Reviews for the Tempo Communications T23403OLV-APC-50U

Tempo Communications T23403OLV-APC-50U Offers

The 650 nm VFL VisiTester feature mixes a VFL in with the test signal during Autotest. It operates as a stand-alone VFL or gives positive visual identification of a fiber to be connected during loss testing.

Each fiber needs just one test hook-up and one key press for a complete 2 W and bidirectional loss, length, and ORL test, and the same test method can be used for all fibers in a network, eliminating administration, training, and test errors. Testing is accurate and can take only 5 seconds, directly onto flexible standards-compliant Tier 1 certification reports.

A pair of instruments both display length and bi-directional loss, and ORL each end, in real time, with no need to specify master/slave instruments. A single instrument can also be used as a stand-alone ultra-stable light source and power meter, VFL, ORL meter, or tone generator/detector. The ORL meter is calibrated with 50 u fiber, and works on 62.5u fiber with an appropriate dB offset.

Features

  • 25% of the size and weight, 7x the battery life of competitors
  • Bidirectional Autotest loss, length and ORL testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass and Fail display
  • 8000 fiber memory and USB Flash Drive file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1% accuracy
  • Traceable calibration reports: Power meter and linearity, source λ and stability, ORL
  • 80 hours alkaline battery life
  • 3 Year warranty and calibration cycle
  • EF compliant multimode sources

Tempo Communications T23403OLV-APC-50U Specifications

Source
Modulated Output 270 Hz, 1 kHz, 2 kHz ±2%, 12 Multi-Fiber ID tones
Output Wavelength 850 and 1300 nm LED APC
VisiTester
Output Power -27 dBm ±1 dB at 62.5 μm
Adjust Output Power Fixed
Short Term Stability For 15 minutes
  • Typical ±2°C
    After warm up
    ORL < -25 dB
    • 0.01 dB
Stability Over Temperature 0.35 dB
Wavelength Drift Typical 0.4 nm per °C
Reconnection Repeatability 0.05 dB at 95% Confidence
Mode Controlled 50/125μm compliant:
  • IEC 61280-4-1 {Ed.1.0}
  • TIA 526-14A
  • TIA TSB-178
2-way Autotest Only
Length Range 4.5 dB at 50 μm
Length Accuracy 0.01% ± 4 meters
Length Resolutions 1 m (0.000 to 9.999 Km)
10 m (10.00 to 99.99 Km)
100 m (100.0 to 127.9 Km)
2-way Autotest
Loss Range 21.5 dB at 50 μm
Loss Repeatability and Loss Linearity 0.06 dB
1-way Autotest
Loss Range 21.5 at 50 μm
Loss Repeatability and Loss Linearity 0.06 dB
Meter
Detector Type InGaAs
Response Wavelength 600 and 1700 nm
Calibration Wavelengths 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
Accuracy 1% (0.06 dB)
Mid-range Linearity 0.04 dB (typical)
Power Range 10 to -60 dBm (780 and 980, and 1590 and 1650 nm)
10 to -70 dBm (1270 and 1650 nm)
Total Uncertainty 0.3 dB maximum
Resolution 0.01 dB
Polarization Sensitivity < 0.05 dB typical
ID Tone Detection and Autotest Sensitivity Up to -50 dBm
Tone Detection 150 to 9999 Hz ±1%
Orl Range 0 to 27.5 dB at 50 μm
Orl Port Isolation > 25 dB
Orl Accuracy 0.2 dB
Orl Resolution 0.01 dB (at 0 to 30 dB)
0.1 dB (at 30 to 45 dB)
VisiTester Wavelength 650 ±5 nm
VisiTester Power 0 dBm ±1 dB at SMF
VisiTester Laser Safety Class 1
IEC60825-2
VisiTester Blink Rate - Manual CW or 2 Hz
Autotest 1-way: Compatible with other T23400 and T27400 models
2-way: Compatible with identical model only
Usb Interfaces Micro-USB for power and software
USB-A Flash Drive
Software KITS - free download
Power Battery
External power via micro-USB
Battery Life Laser and LED source: Typically 80 hours in autotest
Power meter: Typically 1000 hours
Battery Type 2x AA (LR6) Alkaline
2x AA NiMH AA (rechargeable via micro-USB)
Auto Off Selectable
Display 2.9 x 2.2" (74 x 55 mm) high contrast LCD
Case Polycarbonate body
Rubber edges and corners
Moisture resistance
1 m drop tested
Memory For 8000 fibers
Unlimited on USB Flash Drive
Temperature Operating temperature: 5 to 131°F (-15 to 55°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Relative Humidity 0 to 95%
Calibration Validity ISO/IEC 17025 3 years
Warranty 3 years
Dimensions 7.4 x 4.1 x 1.4" (190 x 105 x 35 mm)
Weight 0.93 lbs (0.42 kg)
Shipping Weight 3.3 lbs (1.5 kg)

What's included with the Tempo Communications T23403OLV-APC-50U

  • Tempo T23403OLV-APC-50U Ultra-Stable 2 W Loss Length ORL Tester with 850 - 1330 nm port, and InGaAs detector type
  • Three-Years Warranty

Ask a question about Tempo T23403OLV-APC-50U Ultra-Stable 2 W Loss Length ORL Tester Calibrated for 50 um with VisiTester, 850 and 1330 nm port

Customer Reviews for the Tempo Communications T23403OLV-APC-50U

More Tempo Communications Products