The rugged construction inside and out and the 3 x 3" (7.6 x 7.6 cm) cold cathode fluorescent display's bright backlight make it ideal for technicians in many different fields.
The rugged construction inside and out and the 3 x 3" (7.6 x 7.6 cm) cold cathode fluorescent display's bright backlight make it ideal for technicians in many different fields.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Digital Multimeters category for similar products.
Or let's do a search and help you find what you need:
Features
Applications
VERTICAL | |
---|---|
Bandwidth | 20 MHz w/SP60B 10:1 Probe 10 MHz w/Shielded Test Leads |
Sample Rate | |
Real Time | 25 Megasamples per Second up to 2 MHz |
Equivalent Time | 500 Megasamples per Second > 2 MHz |
Sensitivity | 50mV TO 200V/div 1,2,5 Sequence |
Coupling | AC, DC, GND |
Resolution | 8 bits |
Accuracy | ± (3% + 0.05 range/div) |
HORIZONTAL | |
Modes | Single, Normal, Auto |
Samples per Division | 25 |
Accuracy | Equivalent Time: ± (0.5% + 0.08 time/div)
Real Time: ± (0.1% + 0.04 time/div) |
TRIGGER | |
Source | Internal |
Modes | Free Run, Normal |
Sensitivity | Equivalent Time: 3 divisions or more Real Time: 2 divisions or more |
TREND MODE | |
Plot Time | 30 sec/div to 1 hour/div |
Plot Data Type | Max/Min Selectable |
Memory | 2 Screens |
TRUE RMS DMM | |
DCV (CH1, CH2) Basic Accuracy | 400mV, 4, 40, 400, 600V ± (0.5% + 5 digits) |
ACV (CH1, CH2) Basic Accuracy | 400mV, 4, 40, 400, 600V ± (1% + 10 digits) |
Frequency (CH1, CH2) Basic Accuracy | 1 Hz to 20 MHz ± (0.5% + 5 digits) |
Ohm (CH1 only) Basic Accuracy | 400, 4k, 40k, 400k, 4M, 20M ± (0.5% + 5 digits) |
Continuity (CH1 only) | Sounds < 0.1k ohm, ± (2% + 5 digits) |
VERTICAL | |
---|---|
Bandwidth | 20 MHz w/SP60B 10:1 Probe 10 MHz w/Shielded Test Leads |
Sample Rate | |
Real Time | 25 Megasamples per Second up to 2 MHz |
Equivalent Time | 500 Megasamples per Second > 2 MHz |
Sensitivity | 50mV TO 200V/div 1,2,5 Sequence |
Coupling | AC, DC, GND |
Resolution | 8 bits |
Accuracy | ± (3% + 0.05 range/div) |
HORIZONTAL | |
Modes | Single, Normal, Auto |
Samples per Division | 25 |
Accuracy | Equivalent Time: ± (0.5% + 0.08 time/div)
Real Time: ± (0.1% + 0.04 time/div) |
TRIGGER | |
Source | Internal |
Modes | Free Run, Normal |
Sensitivity | Equivalent Time: 3 divisions or more Real Time: 2 divisions or more |
TREND MODE | |
Plot Time | 30 sec/div to 1 hour/div |
Plot Data Type | Max/Min Selectable |
Memory | 2 Screens |
TRUE RMS DMM | |
DCV (CH1, CH2) Basic Accuracy | 400mV, 4, 40, 400, 600V ± (0.5% + 5 digits) |
ACV (CH1, CH2) Basic Accuracy | 400mV, 4, 40, 400, 600V ± (1% + 10 digits) |
Frequency (CH1, CH2) Basic Accuracy | 1 Hz to 20 MHz ± (0.5% + 5 digits) |
Ohm (CH1 only) Basic Accuracy | 400, 4k, 40k, 400k, 4M, 20M ± (0.5% + 5 digits) |
Continuity (CH1 only) | Sounds < 0.1k ohm, ± (2% + 5 digits) |