Operating Temperature Range | 14°F to +1227°F (-10°C to +50°C) |
Battery / Battery Life | Li-Ion 3.7V 6+ Hours |
Charger Input | USB Type-C |
Plug | Natural Gas (LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse) |
Fuel Ranges | mbar, psi, inH2O, mmH2O, kPa, inHg, mmHg, mH2O |
Pressure | Backlit Graphic LCD |
Display | 100 sets or readings (30 sets for CO build Up), multiple pages |
Data Storage | 24 Hour Real-Time Clock |
Time and Date | 7.28" (185mm) x 4.92" (125mm) x 2.56" (65mm) |
Dimensions | 1.83lbs (830g) |
Weight | EN50379: Parts 1-3 |
Conforms to | Pistol Grip with Stainless Steel Shaft |
Construction | 8.2' (2500mm) |
Hose Length | 7.9" (200mm) |
Insertion Length | +/- 0.3% of fullscale, +/- 2°F (+/-1°C) |
X Type Thermocouple Accuracy | 1472°F (800°C) |
Maximum Temperature | 0.25% |
Oxygen Range | 0-10,000 ppm |
Carbon Monoxide (low) Range | 0-100,000 ppm |
Carbon Monoxide (high) Range | 0-5000ppm |
Nitric Oxide × Range | 0.25% |
Carbon Dioxide Range | 0.99% |
CO/CO2 Ratio Range | 0.100% |
Combustion Efficiency Range | 0.01 |
Oxygen Resolution | 1 ppm |
Carbon Monoxide (low) Resolution | 1.0E-5 |
Carbon Monoxide (high) Resolution | 1 ppm |
Nitric Oxide × Resolution | 0.001 |
Carbon Dioxide Resolution | 0.001 |
CO/CO2 Ratio Resolution | 0.001 |
Oxygen Accuracy | +/- 0.3% |
Carbon Monoxide (low) Accuracy | +/-0.2ppm +/- 5 ppm | (>=100ppm) +/- 5% |
Carbon Monoxide (high) Accuracy | >10,000ppm: +/- 10% |
Nitric Oxide × Accuracy | +/- 5 ppm (100ppm) | +/- 5% (>=1000ppm) | +/- 10% (>1000ppm) |
Carbon Dioxide Accuracy | Calculated |
CO/CO2 Ratio Accuracy | Calculated |
Combustion Efficiency Accuracy | Calculated |
Operating Temperature Range | 14°F to +1227°F (-10°C to +50°C) |
Battery / Battery Life | Li-Ion 3.7V 6+ Hours |
Charger Input | USB Type-C |
Plug | Natural Gas (LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse) |
Fuel Ranges | mbar, psi, inH2O, mmH2O, kPa, inHg, mmHg, mH2O |
Pressure | Backlit Graphic LCD |
Display | 100 sets or readings (30 sets for CO build Up), multiple pages |
Data Storage | 24 Hour Real-Time Clock |
Time and Date | 7.28" (185mm) x 4.92" (125mm) x 2.56" (65mm) |
Dimensions | 1.83lbs (830g) |
Weight | EN50379: Parts 1-3 |
Conforms to | Pistol Grip with Stainless Steel Shaft |
Construction | 8.2' (2500mm) |
Hose Length | 7.9" (200mm) |
Insertion Length | +/- 0.3% of fullscale, +/- 2°F (+/-1°C) |
X Type Thermocouple Accuracy | 1472°F (800°C) |
Maximum Temperature | 0.25% |
Oxygen Range | 0-10,000 ppm |
Carbon Monoxide (low) Range | 0-100,000 ppm |
Carbon Monoxide (high) Range | 0-5000ppm |
Nitric Oxide × Range | 0.25% |
Carbon Dioxide Range | 0.99% |
CO/CO2 Ratio Range | 0.100% |
Combustion Efficiency Range | 0.01 |
Oxygen Resolution | 1 ppm |
Carbon Monoxide (low) Resolution | 1.0E-5 |
Carbon Monoxide (high) Resolution | 1 ppm |
Nitric Oxide × Resolution | 0.001 |
Carbon Dioxide Resolution | 0.001 |
CO/CO2 Ratio Resolution | 0.001 |
Oxygen Accuracy | +/- 0.3% |
Carbon Monoxide (low) Accuracy | +/-0.2ppm +/- 5 ppm | (>=100ppm) +/- 5% |
Carbon Monoxide (high) Accuracy | >10,000ppm: +/- 10% |
Nitric Oxide × Accuracy | +/- 5 ppm (100ppm) | +/- 5% (>=1000ppm) | +/- 10% (>1000ppm) |
Carbon Dioxide Accuracy | Calculated |
CO/CO2 Ratio Accuracy | Calculated |
Combustion Efficiency Accuracy | Calculated |