Engineered for fast, future-ready certification, the LanTEK IV-S certifies copper and fiber links up to Cat8.2 and performs full Cat6A tests in just 7 seconds. Operating at an extended 3000 MHz, this model includes PL/CH adapters and supports TCL and Resistance Unbalance measurements for advanced compliance. Built without Wi-Fi, for secure, controlled deployments.
Engineered for fast, future-ready certification, the LanTEK IV-S certifies copper and fiber links up to Cat8.2 and performs full Cat6A tests in just 7 seconds. Operating at an extended 3000 MHz, this model includes PL/CH adapters and supports TCL and Resistance Unbalance measurements for advanced compliance. Built without Wi-Fi, for secure, controlled deployments.
The LanTEK IV-S copper and fiber data cable certifier is the future of cable certification and testing. Saving you time it will test and save a Cat6A link in 7 seconds and certifies links up to Cat8.1 and Cat8.2, including TCL and Resistance Unbalance measurements.
Features
Battery | Lithium-ion, 7.4 V DC, 6.6Ah (48.84 Wh typical) Input: 12 V/2 A DC Typical operating time: 8 hours (new battery running a Cat6 test every 20 seconds, full backlight) Charge time: <4 hours quick charge with battery removed from handset, <8 hours inside handset Input power: Handset DC 12 to 15 V, 2A |
Line/Mains Power Adapters | Input: AC 110 to 240 V, 50/60 Hz Output: 12 - 2500mA, 5.5mm x 2.5mm x 12mm, center positive |
Display | IPS, 480x854 pixels, 5” diagonal, capacitive touch LCD, scratch-resistant acrylic screen |
Connectivity | Test module port: 120 pin ultra-low crosstalk module interface USC C (USB 2.0), USB A (USB 2.0), 3.5 mm talk set jack, power/charging jack, integrated Wi-Fi (2.4/5 GHz bands) 802.11a/b/g/n (model available with Wi-Fi disabled) |
Input Methods | Capacitive touchscreen, USB keyboard, USB mouse |
Frequency Range | 1 to 3000 MHz |
CPU Module (Main Handset) | CPU: 1.0 GHz, 32-bit Cortex™ A9 processor, Dual-core ARM7 System memory: 1024 MB RAM System storage: 16 GB eMMC Flash |
CPU Module (Remote Handset) | CPU: 900 MHz, 32-bit Cortex™ A7 processor, Single-core ARM7 System memory: 128 MB RAM System storage: 8 GB eMMC Flash |
Test Storage | Non-volatile flash, capacity for 5000 tests with graphs |
Data Transfer | Export to USB flash drive (supports up to 256 GB, FAT32 format required) |
Measurements | Twisted pair copper cable: Wire map, DC loop resistance length, capacitance, NEXT, insertion loss, ACR-N, return loss, average impedance, propagation delay, delay skew, power sum NEXT, power sum ACR-N, ACR-F, power sum ACR-F, TCL (Transverse Conversion Loss), ELTCTL (EqualLevel Transverse Conversion Transfer Loss, DC loop resistance, DC resistance unbalance (pair-to-pair/intra-pair),Time Domain NEXT and Time Domain Return Loss fault finding identifies the location of NEXT and RL events Fibre optic cabling (optional FiberTEK IV test modules): Dual-wavelength insertion loss (each fiber), length Supported wavelengths: Multimode 850/1300nm, Single-mode 1310/1550 nm Fault location with integrated laser visual fault locator |
Supported Cable Types | ANSI/TIA Category 3, 4, 5, 5E, 6, 6A and 8: 100Ω ANSI/SCTE Series 59, 6 and 11: 75 Ω, RG-58: 50 Ω ISO/IEC Class C, D, E, EA, F, FA and 8: 100Ω OM1-OM5 multimode and OS1-OS2 single-mode fibre optic cable OM1–OM5 multimode and OS1–OS2 single-mode fiber |
Test Interface | 120-pin ultra-low crosstalk connector |
Supported Connectors | TIA Cat 6/6A, ISO Class E/EA RJ-45 permanent link adapters TIA Cat 8.1, ISO Class I/II RJ-45 permanent link adapters TIA Cat 6/6A, ISO Class E/EA RJ-45 channel adapters TIA Cat 8.1, ISO Class I/II RJ-45 channel adapters TERA/GG45/EC7 (MMCPRO3000) Cat 8.2 universal adapters for channel and permanent link testing M12-X, 4-pair Cat 6A universal adapters for channel and permanent link testing M12-D, 2-pair Cat 5e universal adapters for channel and permanent link testing Coaxial adapters for 50/75-ohm cable with female BNC connector. Tests to 500 MHz with LanTEK IV-S 500, or 3000 MHz with LanTEK IV-S 3000 depending on selected standard. BNC to F-type adapter included. SC/FC/ST fibre optic connectors included with FiberTEK IV kits. LC adapter kit optional (sold separately) |
Test Times | Copper: 7 seconds to 1000 MHz 23 seconds to 3000 MHz Including required/optional tests Fiber: 14 seconds dual-wavelength, one direction 28 seconds, dual-wavelength, bi-directional |
Wiremap Distance to Fault Display Resolution | 3.9" (10 cm) |
Length Measurement | Copper: 0 to 1960' (0 to 600 m) Fiber: 0 to 32,808' (0 to 10 km) Display resolution: 1' (0.1 m) |
DC Resistance | Range: 0.02 to 200 ohms Display resolution: 0.1 ohms |
Propagation Delay | Measurement range: 1 ns to 1 s Display resolution: 1 ns |
RF Measurement | Accuracy: ISO/IEC 61935-1 Ed 5, ANSI/TIA-1152-A Display resolution: 0.1 dB |
Operating Temperature | 32 to 113°F (0 to 45°C), non-condensing |
Storage Temperature | -4 to 158°F (-20 to 70°C), non-condensing |
Shock/Vibration | MIL-PRF-28800F, Class 3 (design-compliant) |
User Interface Languages | Chinese, English, French, German, Italian, Portuguese, Russian, Spanish |
Accuracy Certification | ETL Verified: ANSI/TIA-1152-A Level 2G, IEC 61935-1 Level VI |
PC Software | TREND AnyWARE Cloud Web client – requires HTML 5 compatible browser TREND AnyWARE Desktop software Requirements: Microsoft Windows 10 or higher, 2 GB RAM, 500 MB hard disk + 1 GB for every 1,500 Category 6 tests |
Conformance | IEC 61010-1:2010 Ed 3 - Safety requirements for electrical equipment for measurement, control and laboratory use. EN61326-1:2013 – Electrical equipment for measurement, control and laboratory use. EMC requirements. EN55011:2009 + A2:2010 – Industrial, scientific and medical equipment. Radio frequency disturbance characteristics. ENGl000-4-2:2009 - Electrostatic Discharge Immunity Test EN61000-4-3:2006+A2:2010 - Radiated, radio-frequency, electromagnetic field immunity test EN61000-4-4:2004+Al:2010 - Electrical Fast Transient / Burst Immunity Test ENGl000-4-5:2006 - Surge Immunity Test EN61000-4-6:2009 - Immunity to conducted disturbances, induced by radiofrequency fields EN61000-4-11:2004 - Voltage dips, short interruptions and voltage variations immunity tests Instrument: CE, C-Tick, FCC Part 15, Class A Battery: DOT 49 CFR 173.185, UN Part IV – section 38.3 |
Warranty | Instrument: one (1) year from date of delivery Accessories: one (1) year from date of delivery Batteries: six (6) months from date of delivery |
Dimensions | 10 x 5 x 2.1" (25.4 x 12.7 x 5.3 cm) |
Weight (with battery) |
Display: 2.35 lbs (1.1 kg) Remote: 2.30 lbs (1.0 kg) |
Click on a category to view a selection of compatible accessories with the TREND Networks R163011 LanTEK IV-S Copper and Fiber Data Cable Certifier with PL/CH adapters, No Wi-Fi, 3000 MHz.
Battery | Lithium-ion, 7.4 V DC, 6.6Ah (48.84 Wh typical) Input: 12 V/2 A DC Typical operating time: 8 hours (new battery running a Cat6 test every 20 seconds, full backlight) Charge time: <4 hours quick charge with battery removed from handset, <8 hours inside handset Input power: Handset DC 12 to 15 V, 2A |
Line/Mains Power Adapters | Input: AC 110 to 240 V, 50/60 Hz Output: 12 - 2500mA, 5.5mm x 2.5mm x 12mm, center positive |
Display | IPS, 480x854 pixels, 5” diagonal, capacitive touch LCD, scratch-resistant acrylic screen |
Connectivity | Test module port: 120 pin ultra-low crosstalk module interface USC C (USB 2.0), USB A (USB 2.0), 3.5 mm talk set jack, power/charging jack, integrated Wi-Fi (2.4/5 GHz bands) 802.11a/b/g/n (model available with Wi-Fi disabled) |
Input Methods | Capacitive touchscreen, USB keyboard, USB mouse |
Frequency Range | 1 to 3000 MHz |
CPU Module (Main Handset) | CPU: 1.0 GHz, 32-bit Cortex™ A9 processor, Dual-core ARM7 System memory: 1024 MB RAM System storage: 16 GB eMMC Flash |
CPU Module (Remote Handset) | CPU: 900 MHz, 32-bit Cortex™ A7 processor, Single-core ARM7 System memory: 128 MB RAM System storage: 8 GB eMMC Flash |
Test Storage | Non-volatile flash, capacity for 5000 tests with graphs |
Data Transfer | Export to USB flash drive (supports up to 256 GB, FAT32 format required) |
Measurements | Twisted pair copper cable: Wire map, DC loop resistance length, capacitance, NEXT, insertion loss, ACR-N, return loss, average impedance, propagation delay, delay skew, power sum NEXT, power sum ACR-N, ACR-F, power sum ACR-F, TCL (Transverse Conversion Loss), ELTCTL (EqualLevel Transverse Conversion Transfer Loss, DC loop resistance, DC resistance unbalance (pair-to-pair/intra-pair),Time Domain NEXT and Time Domain Return Loss fault finding identifies the location of NEXT and RL events Fibre optic cabling (optional FiberTEK IV test modules): Dual-wavelength insertion loss (each fiber), length Supported wavelengths: Multimode 850/1300nm, Single-mode 1310/1550 nm Fault location with integrated laser visual fault locator |
Supported Cable Types | ANSI/TIA Category 3, 4, 5, 5E, 6, 6A and 8: 100Ω ANSI/SCTE Series 59, 6 and 11: 75 Ω, RG-58: 50 Ω ISO/IEC Class C, D, E, EA, F, FA and 8: 100Ω OM1-OM5 multimode and OS1-OS2 single-mode fibre optic cable OM1–OM5 multimode and OS1–OS2 single-mode fiber |
Test Interface | 120-pin ultra-low crosstalk connector |
Supported Connectors | TIA Cat 6/6A, ISO Class E/EA RJ-45 permanent link adapters TIA Cat 8.1, ISO Class I/II RJ-45 permanent link adapters TIA Cat 6/6A, ISO Class E/EA RJ-45 channel adapters TIA Cat 8.1, ISO Class I/II RJ-45 channel adapters TERA/GG45/EC7 (MMCPRO3000) Cat 8.2 universal adapters for channel and permanent link testing M12-X, 4-pair Cat 6A universal adapters for channel and permanent link testing M12-D, 2-pair Cat 5e universal adapters for channel and permanent link testing Coaxial adapters for 50/75-ohm cable with female BNC connector. Tests to 500 MHz with LanTEK IV-S 500, or 3000 MHz with LanTEK IV-S 3000 depending on selected standard. BNC to F-type adapter included. SC/FC/ST fibre optic connectors included with FiberTEK IV kits. LC adapter kit optional (sold separately) |
Test Times | Copper: 7 seconds to 1000 MHz 23 seconds to 3000 MHz Including required/optional tests Fiber: 14 seconds dual-wavelength, one direction 28 seconds, dual-wavelength, bi-directional |
Wiremap Distance to Fault Display Resolution | 3.9" (10 cm) |
Length Measurement | Copper: 0 to 1960' (0 to 600 m) Fiber: 0 to 32,808' (0 to 10 km) Display resolution: 1' (0.1 m) |
DC Resistance | Range: 0.02 to 200 ohms Display resolution: 0.1 ohms |
Propagation Delay | Measurement range: 1 ns to 1 s Display resolution: 1 ns |
RF Measurement | Accuracy: ISO/IEC 61935-1 Ed 5, ANSI/TIA-1152-A Display resolution: 0.1 dB |
Operating Temperature | 32 to 113°F (0 to 45°C), non-condensing |
Storage Temperature | -4 to 158°F (-20 to 70°C), non-condensing |
Shock/Vibration | MIL-PRF-28800F, Class 3 (design-compliant) |
User Interface Languages | Chinese, English, French, German, Italian, Portuguese, Russian, Spanish |
Accuracy Certification | ETL Verified: ANSI/TIA-1152-A Level 2G, IEC 61935-1 Level VI |
PC Software | TREND AnyWARE Cloud Web client – requires HTML 5 compatible browser TREND AnyWARE Desktop software Requirements: Microsoft Windows 10 or higher, 2 GB RAM, 500 MB hard disk + 1 GB for every 1,500 Category 6 tests |
Conformance | IEC 61010-1:2010 Ed 3 - Safety requirements for electrical equipment for measurement, control and laboratory use. EN61326-1:2013 – Electrical equipment for measurement, control and laboratory use. EMC requirements. EN55011:2009 + A2:2010 – Industrial, scientific and medical equipment. Radio frequency disturbance characteristics. ENGl000-4-2:2009 - Electrostatic Discharge Immunity Test EN61000-4-3:2006+A2:2010 - Radiated, radio-frequency, electromagnetic field immunity test EN61000-4-4:2004+Al:2010 - Electrical Fast Transient / Burst Immunity Test ENGl000-4-5:2006 - Surge Immunity Test EN61000-4-6:2009 - Immunity to conducted disturbances, induced by radiofrequency fields EN61000-4-11:2004 - Voltage dips, short interruptions and voltage variations immunity tests Instrument: CE, C-Tick, FCC Part 15, Class A Battery: DOT 49 CFR 173.185, UN Part IV – section 38.3 |
Warranty | Instrument: one (1) year from date of delivery Accessories: one (1) year from date of delivery Batteries: six (6) months from date of delivery |
Dimensions | 10 x 5 x 2.1" (25.4 x 12.7 x 5.3 cm) |
Weight (with battery) |
Display: 2.35 lbs (1.1 kg) Remote: 2.30 lbs (1.0 kg) |
Click on a category to view a selection of compatible accessories with the TREND Networks R163011 LanTEK IV-S Copper and Fiber Data Cable Certifier with PL/CH adapters, No Wi-Fi, 3000 MHz.