Work with this thermometer that measures air temperature, relative humidity, dew point, type K, and IR temperature. Additionally, this thermometer features a 30:1 IR thermometer with a laser pointer, 0.95 fixed emissivity, a dual backlit LCD, and is °F/°C switchable. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Work with this thermometer that measures air temperature, relative humidity, dew point, type K, and IR temperature. Additionally, this thermometer features a 30:1 IR thermometer with a laser pointer, 0.95 fixed emissivity, a dual backlit LCD, and is °F/°C switchable. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Features
Applications
| Temperature | Air: -4 to 140°F (-20 to 60°C) Type K: 148 to 2501°F (-100 to 1372°C) Infrared: -58 to 932°F (-50 to 500°C) |
| Accuracy | ±(2% + 2°F/1°C) ±(3% + 4°F/2°C) ±2% or 4°F/2°C |
| Relative Humidity | 10 to 90%RH Accuracy: ±2% RH |
| Wet Bulb | -6.88 to 140°F (-21.6 to 60°C) |
| Dew Point | 90.4 to 140°F (-68 to 60°C) |
| Resolution | 0.1°F/°C; 0.1% RH |
| Display | Dual display multi-function LCD with 9999 counts |
| Data Hold | Freezes displayed reading |
| Sampling Rate | 1 reading per second |
| Sensors | Relative humidity: Capacitance Air temperature: Thermistor |
| IR | Distance to spot ratio: 30:1 Spectral response: 6 to 14 μm Emissivity: 0.95 fixed |
| Minimum-Maximum | Record and recall lowest and highest readings |
| Auto Power OFF | Automatic shut off after 15 minutes (can be disabled) |
| PC Interface | USB PC Communication with supplied software and cable for data acquisition |
| Indication | Over range: Dashes appears on the LCD Low battery indication: Battery symbol appears on the LCD |
| Power Supply | 9 V battery |
| Operating Conditions | Meter: 32 to 122°F (0 to 50°C); 80% RH maximum |
| Dimensions | 10.1 x 3 x 2" (257 x 76 x 53 mm) |
| Weight | 12.5 oz (355 g) |
| Temperature | Air: -4 to 140°F (-20 to 60°C) Type K: 148 to 2501°F (-100 to 1372°C) Infrared: -58 to 932°F (-50 to 500°C) |
| Accuracy | ±(2% + 2°F/1°C) ±(3% + 4°F/2°C) ±2% or 4°F/2°C |
| Relative Humidity | 10 to 90%RH Accuracy: ±2% RH |
| Wet Bulb | -6.88 to 140°F (-21.6 to 60°C) |
| Dew Point | 90.4 to 140°F (-68 to 60°C) |
| Resolution | 0.1°F/°C; 0.1% RH |
| Display | Dual display multi-function LCD with 9999 counts |
| Data Hold | Freezes displayed reading |
| Sampling Rate | 1 reading per second |
| Sensors | Relative humidity: Capacitance Air temperature: Thermistor |
| IR | Distance to spot ratio: 30:1 Spectral response: 6 to 14 μm Emissivity: 0.95 fixed |
| Minimum-Maximum | Record and recall lowest and highest readings |
| Auto Power OFF | Automatic shut off after 15 minutes (can be disabled) |
| PC Interface | USB PC Communication with supplied software and cable for data acquisition |
| Indication | Over range: Dashes appears on the LCD Low battery indication: Battery symbol appears on the LCD |
| Power Supply | 9 V battery |
| Operating Conditions | Meter: 32 to 122°F (0 to 50°C); 80% RH maximum |
| Dimensions | 10.1 x 3 x 2" (257 x 76 x 53 mm) |
| Weight | 12.5 oz (355 g) |