Ideal for combustion analysis, this flue gas analyzer offers essential information for installing and maintaining gas appliances, direct CO2 measurement, and features a 30-second start-up time. In addition, it is easy to use with a rugged design and has multiple sensor protections, altitude compensation, and a heat exchanger test.
Ideal for combustion analysis, this flue gas analyzer offers essential information for installing and maintaining gas appliances, direct CO2 measurement, and features a 30-second start-up time. In addition, it is easy to use with a rugged design and has multiple sensor protections, altitude compensation, and a heat exchanger test.
Features
Functions
Applications
Temperature Measurement | |
Flue Temperature | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±(0.3% rdg +3.6°F [2°C]) |
Inlet Temperature (Internal Sensor) | Range: 32 to 122°F (0 to 50°C) Resolution: 0.1°F (0.1°C) Accuracy: ±2°F (1°C) |
Inlet Temperature (External Sensor) | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.2° (0.1°C) Accuracy: ±1.0°F (0.5°C) |
Flue Gas Measurement | |
Carbon Monoxide | Range: 0 to 2000 ppm Resolution: 1 ppm Accuracy: ±3 ppm or ±5% rdg (whichever is greater) |
Carbon Dioxide | Range: 0 to 20% Resolution: 0.1% Accuracy: ±0.3% volume |
Calculations | |
Oxygen | Range: 0 to 21% Resolution: 0.1% Accuracy: ±0.3% volume |
Efficiency (Net or Gross) | Range: 0 to 99.9% Resolution: 0.1% Accuracy: ±1% rdg |
Excess Air | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±0.2% rdg |
General Specifications | |
Pre-Programmed Fuels | Natural gas, propane, LPG, light oil, heavy oil, bio oil, pellets |
Environmental Conditions | Operating temperature: 32 to 113°F (0 to 45°C) Storage temperature: 0 to 113°F (-18 to 50°C) Humidity: 15 to 90% RH |
Power Supply | Rechargeable batteries, USB charging Battery life: >8 hours (continuous with pump on) |
Certification | TUV-tested and certified to EN 50379, Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (BimSchV) |
Dimensions | 8.54 x 4.18 x 1.86" (216.92 x 106.17 x 47.24 mm) |
Weight | 1.51 lbs (0.68 kg) |
Click on a category to view a selection of compatible accessories with the UEi C161 Residential Combustion Analyzer with direct CO2 measurement, 32 to 1112°F, 2000 ppm.
Temperature Measurement | |
Flue Temperature | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.1°F (0.1°C) Accuracy: ±(0.3% rdg +3.6°F [2°C]) |
Inlet Temperature (Internal Sensor) | Range: 32 to 122°F (0 to 50°C) Resolution: 0.1°F (0.1°C) Accuracy: ±2°F (1°C) |
Inlet Temperature (External Sensor) | Range: 32 to 1112°F (0 to 600°C) Resolution: 0.2° (0.1°C) Accuracy: ±1.0°F (0.5°C) |
Flue Gas Measurement | |
Carbon Monoxide | Range: 0 to 2000 ppm Resolution: 1 ppm Accuracy: ±3 ppm or ±5% rdg (whichever is greater) |
Carbon Dioxide | Range: 0 to 20% Resolution: 0.1% Accuracy: ±0.3% volume |
Calculations | |
Oxygen | Range: 0 to 21% Resolution: 0.1% Accuracy: ±0.3% volume |
Efficiency (Net or Gross) | Range: 0 to 99.9% Resolution: 0.1% Accuracy: ±1% rdg |
Excess Air | Range: 0 to 119.9% Resolution: 0.1% Accuracy: ±0.2% rdg |
General Specifications | |
Pre-Programmed Fuels | Natural gas, propane, LPG, light oil, heavy oil, bio oil, pellets |
Environmental Conditions | Operating temperature: 32 to 113°F (0 to 45°C) Storage temperature: 0 to 113°F (-18 to 50°C) Humidity: 15 to 90% RH |
Power Supply | Rechargeable batteries, USB charging Battery life: >8 hours (continuous with pump on) |
Certification | TUV-tested and certified to EN 50379, Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (BimSchV) |
Dimensions | 8.54 x 4.18 x 1.86" (216.92 x 106.17 x 47.24 mm) |
Weight | 1.51 lbs (0.68 kg) |
Click on a category to view a selection of compatible accessories with the UEi C161 Residential Combustion Analyzer with direct CO2 measurement, 32 to 1112°F, 2000 ppm.