The deluxe duct CO2 sensor allows ventilation systems to be controlled by the amount of CO2 present in a space and detects fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for space at given time-saving energy.
The deluxe duct CO2 sensor allows ventilation systems to be controlled by the amount of CO2 present in a space and detects fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for space at given time-saving energy.
The deluxe duct CO₂ sensor allows ventilation systems to be controlled by the amount of CO₂ present in a space and detects fluctuations in CO₂ levels and signal ventilation systems to provide an inlet of fresh air optimal for space at given time-saving energy.
Features
Applications
| Input Power | Class 2; 20 to 30 VDC/24 AC 50/60 Hz; 100 mA max |
| Analog Output | 4 to 20 mA (clipped and capped)/0 to 5 VDC/0 to 10 VDC (selectable) |
| Operating Temperature Range | CDL: 32 to 122°F (0 to 50°C) |
| Operating Humidity Range | 0 to 95% RH non-condensing |
| Housing Material | High-impact ABS plastic |
| Terminal Block Torque: CDL | 0.2 N-m (2.0 in-lbf) max |
| Terminal Block Wire Size: CWL | 28 to 14 AWG (0.5 to 1.5 mm²) |
| Sensor Type | Non-dispersive infrared, diffusion sampling |
| Output Range | 0 to 2,000/5,000 ppm (programmable) |
| Accuracy | ±30 ppm ±2% of measured value |
| Repeatability | ±20 ppm ±1% of measured value |
| Response Time | <60 seconds for 90% step change |
| HS Sensor | Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 |
| RH Accuracy | ±2% from 10 to 80% RH at 77°F (25°C); NIST-traceable multi-point calibration |
| Hysteresis | 1.5% typical |
| RH Stability | ±1% at 68°F (20°C) annually for 2 years |
| RH Output Range | 0 to 100% RH |
| Temperature Coefficient | ±0.1% RH/°C above or below 77°F (25°C) (typical) |
| Temperature Sensor Type | Solid-state, integrated circuit |
| Temperature Accuracy | ±1°F (±0.5°C) typical |
| Temperature Resolution | 0.2°F (0.1°C) |
| Temperature Output Range | 50 to 95°F (10 to 35°C) |
| 1 Form C (SPDT) | 1 A at 30 VDC, resistive; 30 W max (on wall models, relay is only available in units without the setpoint slider option) |
| Warranty | 3 years limited |
| Input Power | Class 2; 20 to 30 VDC/24 AC 50/60 Hz; 100 mA max |
| Analog Output | 4 to 20 mA (clipped and capped)/0 to 5 VDC/0 to 10 VDC (selectable) |
| Operating Temperature Range | CDL: 32 to 122°F (0 to 50°C) |
| Operating Humidity Range | 0 to 95% RH non-condensing |
| Housing Material | High-impact ABS plastic |
| Terminal Block Torque: CDL | 0.2 N-m (2.0 in-lbf) max |
| Terminal Block Wire Size: CWL | 28 to 14 AWG (0.5 to 1.5 mm²) |
| Sensor Type | Non-dispersive infrared, diffusion sampling |
| Output Range | 0 to 2,000/5,000 ppm (programmable) |
| Accuracy | ±30 ppm ±2% of measured value |
| Repeatability | ±20 ppm ±1% of measured value |
| Response Time | <60 seconds for 90% step change |
| HS Sensor | Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 |
| RH Accuracy | ±2% from 10 to 80% RH at 77°F (25°C); NIST-traceable multi-point calibration |
| Hysteresis | 1.5% typical |
| RH Stability | ±1% at 68°F (20°C) annually for 2 years |
| RH Output Range | 0 to 100% RH |
| Temperature Coefficient | ±0.1% RH/°C above or below 77°F (25°C) (typical) |
| Temperature Sensor Type | Solid-state, integrated circuit |
| Temperature Accuracy | ±1°F (±0.5°C) typical |
| Temperature Resolution | 0.2°F (0.1°C) |
| Temperature Output Range | 50 to 95°F (10 to 35°C) |
| 1 Form C (SPDT) | 1 A at 30 VDC, resistive; 30 W max (on wall models, relay is only available in units without the setpoint slider option) |
| Warranty | 3 years limited |