The deluxe wall CO2 sensor maximizes energy savings while ensuring optimal ventilation and detects fluctuations in CO2 levels. It signals ventilation systems to provide an inlet of fresh air optimal for spaces, giving time-saving energy and ensuring tenant comfort.
The deluxe wall CO2 sensor maximizes energy savings while ensuring optimal ventilation and detects fluctuations in CO2 levels. It signals ventilation systems to provide an inlet of fresh air optimal for spaces, giving time-saving energy and ensuring tenant comfort.
The deluxe wall CO₂ sensor maximizes energy savings while ensuring optimal ventilation and detects fluctuations in CO₂ levels. It signals ventilation systems to provide an inlet of fresh air optimal for spaces, giving time-saving energy and ensuring tenant comfort.
Features
Applications
Input Power | Class 2; 20 to 30 VDC/24 AC 50/60 Hz; 100 mA max |
Analog Output | 4 to 20 mA (clipped and capped)/0 to 5 VDC/0 to 10 VDC (selectable) |
Operating Temperature Range | No humidity option: 32 to 122°F (0 to 50°C); with humidity option: 50 to 95°F (10 to 35°C) |
Operating Humidity Range | 0 to 95% RH non-condensing |
Housing Material | High-impact ABS plastic |
Terminal Block Torque: CWL | 0.22 N-m (2 in-lbf) max |
Terminal Block Wire Size: CWL | 30 to 18 AWG (0.08 to 0.5 mm²) |
Sensor Type | Non-dispersive infrared, diffusion sampling |
Output Range | 0 to 2,000/5,000 ppm (programmable) |
Accuracy | ±30 ppm ±2% of measured value |
Repeatability | ±20 ppm ±1% of measured value |
Response Time | About 60 seconds for 90% step change |
HS Sensor | Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 |
RH Accuracy | ±2% from 10 to 80% RH at 77°F (25°C); NIST-traceable multi-point calibration |
Hysteresis | 1.5% typical |
Stability | ±1% at 68°F (20°C) annually for 2 years |
RH Output Range | 0 to 100% RH |
Temperature Coefficient | ±0.1% RH/°C above or below 77°F (25°C) (typical) |
Temperature Sensor Type | Solid-state, integrated circuit |
Temperature Accuracy | ±1°F (±0.5°C) typical |
Temperature Resolution | 0.2°F (0.1°C) |
Temperature Output Range | 50 to 95°F (10 to 35°C) |
1 Form C (SPDT) | 1 A at 30 VDC, resistive; 30 W max (on wall models, relay is only available in units without the setpoint slider option) |
Warranty | 3 years limited |
Input Power | Class 2; 20 to 30 VDC/24 AC 50/60 Hz; 100 mA max |
Analog Output | 4 to 20 mA (clipped and capped)/0 to 5 VDC/0 to 10 VDC (selectable) |
Operating Temperature Range | No humidity option: 32 to 122°F (0 to 50°C); with humidity option: 50 to 95°F (10 to 35°C) |
Operating Humidity Range | 0 to 95% RH non-condensing |
Housing Material | High-impact ABS plastic |
Terminal Block Torque: CWL | 0.22 N-m (2 in-lbf) max |
Terminal Block Wire Size: CWL | 30 to 18 AWG (0.08 to 0.5 mm²) |
Sensor Type | Non-dispersive infrared, diffusion sampling |
Output Range | 0 to 2,000/5,000 ppm (programmable) |
Accuracy | ±30 ppm ±2% of measured value |
Repeatability | ±20 ppm ±1% of measured value |
Response Time | About 60 seconds for 90% step change |
HS Sensor | Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 |
RH Accuracy | ±2% from 10 to 80% RH at 77°F (25°C); NIST-traceable multi-point calibration |
Hysteresis | 1.5% typical |
Stability | ±1% at 68°F (20°C) annually for 2 years |
RH Output Range | 0 to 100% RH |
Temperature Coefficient | ±0.1% RH/°C above or below 77°F (25°C) (typical) |
Temperature Sensor Type | Solid-state, integrated circuit |
Temperature Accuracy | ±1°F (±0.5°C) typical |
Temperature Resolution | 0.2°F (0.1°C) |
Temperature Output Range | 50 to 95°F (10 to 35°C) |
1 Form C (SPDT) | 1 A at 30 VDC, resistive; 30 W max (on wall models, relay is only available in units without the setpoint slider option) |
Warranty | 3 years limited |