Veris H8026-2400-4 Enercept Power Metering Transducer

Model: H8026-2400-4

Veris H8026-2400-4 Enercept Power Metering Transducer

Model: H8026-2400-4

Three Phase Enercept Power Transducer with N2 Protocol - 2400A, Large.

Three Phase Enercept Power Transducer with N2 Protocol - 2400A, Large.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Veris H8026-2400-4 Offers

The Enercept H8025/H8026 are an innovative three-phase networked power transducers that combines electronics and high accuracy industrial grade CTs in a single package. The need for external electrical enclosures is eliminated, greatly reducing installation time and cost. Color-coordination between voltage leads and CTs makes phase matching easy. Additionally, these transducers automatically detect and compensate for phase reversal, eliminating the concern of CT load orientation. Up to 63 Transducers can be daisy-chained on a single RS-485 network.

Applications

  • Energy managing & performance contracting
  • Submetering for commercial tenants
  • Activity-based costing in commercial and industrial facilities
  • Real-time power monitoring

Cost Effective Meter

  • Monitor energy parameters (kW, kWh, kVAR, PF, Amps, Volts) at up to 63 locations on a single RS-485 network...greatly reduces wiring time and cost
  • Fast split-core installation eliminates the need to remove conductors...saves time and labor
  • Precision electronics and current transformers in a single package-reduces the number of installed components - huge labor savings
  • Smart electronics eliminate CT orientation concerns-fast trouble-free installation
  • ±1% total system accuracy, (10% to 100% of CT rating)

Veris H8026-2400-4 Specifications

Input Primary Voltage 208 to 480VAC RMS
Number of Phases Monitored 1 to 3
Frequency 50/60Hz
Primary Current Up to 2400 amps cont. per phase
Internal Isolation 2000VAC RMS
Insulation Class 600VAC RMS
Temperature Range 0 to 60°C (32 to 140°F)
Humidity Range 0 to 95% non-condensing
Systems Accuracy ±1% of reading from 10% to 100% of the rated current of the CTs
Accomplished by matching the CTs with a meter and calibrating them as a system
Output Physical Characteristics RS-485, 2 wire + shield Baud Rate 9600, 8N1 format
Protocol Modbus RTU
Click here for complete specifications on the Veris H8026-2400-4

What's included with the Veris H8026-2400-4

  • Veris H8026-2400-4 Enercept Power Metering Transducer

Ask a question about Veris H8026-2400-4 Enercept Power Metering Transducer

Customer Reviews for the Veris H8026-2400-4

Veris H8026-2400-4 Offers

The Enercept H8025/H8026 are an innovative three-phase networked power transducers that combines electronics and high accuracy industrial grade CTs in a single package. The need for external electrical enclosures is eliminated, greatly reducing installation time and cost. Color-coordination between voltage leads and CTs makes phase matching easy. Additionally, these transducers automatically detect and compensate for phase reversal, eliminating the concern of CT load orientation. Up to 63 Transducers can be daisy-chained on a single RS-485 network.

Applications

  • Energy managing & performance contracting
  • Submetering for commercial tenants
  • Activity-based costing in commercial and industrial facilities
  • Real-time power monitoring

Cost Effective Meter

  • Monitor energy parameters (kW, kWh, kVAR, PF, Amps, Volts) at up to 63 locations on a single RS-485 network...greatly reduces wiring time and cost
  • Fast split-core installation eliminates the need to remove conductors...saves time and labor
  • Precision electronics and current transformers in a single package-reduces the number of installed components - huge labor savings
  • Smart electronics eliminate CT orientation concerns-fast trouble-free installation
  • ±1% total system accuracy, (10% to 100% of CT rating)

Veris H8026-2400-4 Specifications

Input Primary Voltage 208 to 480VAC RMS
Number of Phases Monitored 1 to 3
Frequency 50/60Hz
Primary Current Up to 2400 amps cont. per phase
Internal Isolation 2000VAC RMS
Insulation Class 600VAC RMS
Temperature Range 0 to 60°C (32 to 140°F)
Humidity Range 0 to 95% non-condensing
Systems Accuracy ±1% of reading from 10% to 100% of the rated current of the CTs
Accomplished by matching the CTs with a meter and calibrating them as a system
Output Physical Characteristics RS-485, 2 wire + shield Baud Rate 9600, 8N1 format
Protocol Modbus RTU
Click here for complete specifications on the Veris H8026-2400-4