Veris PW2LN05BP Pressure Transducer, 0 to 250 psig, NIST certificate

Model: PW2LN05BP

Veris PW2LN05BP Pressure Transducer, 0 to 250 psig, NIST certificate

Model: PW2LN05BP

This high-accuracy wet media sensor is shipped with a NIST calibration certificate for critical monitoring tasks. It features a bypass manifold for maintenance and operates on a reliable 2-wire current loop.

This high-accuracy wet media sensor is shipped with a NIST calibration certificate for critical monitoring tasks. It features a bypass manifold for maintenance and operates on a reliable 2-wire current loop.

Sale Price $1307.60 USD
Regular Price $4830.08 USD
Availability 2 to 3 Weeks
Quantity

Veris PW2LN05BP Offers

The PW2LN05BP series 2-wire, 4 to 20 mA wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability. Easy to use and designed to provide exceptional installation savings, the PW2 series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.

Features

  • LCD Display
  • Operational Range: 0-250 psig
  • The jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Selectable differential units: psid or bard
  • Dual sensor design for improved overpressure tolerance, eliminates the requirement for a bypass valve assembly in most applications
  • Jumper-controlled electronic surge dampening for high stability
  • Pushbutton zero calibration - no trim pots to adjust, maintain accuracy and reduce callbacks with automatic zero calibration
  • 2-wire transmitter output
  • User-selectable output
  • NIST certified
  • 2 times of maximum full scale range proof pressure
  • 5 times of maximum full scale range burst pressure
  • Mounted bypass assembly


Optional Accessories: AA11, AA12, AA13

Veris PW2LN05BP Specifications

Application Zone Plant Room
Application Pump and Compressor Differential Pressure | Chiller Differential Pressure Monitoring
Brand Veris
Burst Pressure 1250 psi (85 bar)
Calibration Certificate NIST Certificate
Dimension Depth 2.6" (67 mm)
Dimension Height 12" (305 mm)
Dimension Width 8.7" (221 mm)
Display Size 0.7" x 1.4" (17 mm x 36 mm)
Display Type LCD
Electrical Wiring 2-wires (loop-powered)
Enclosure Material Powder Coated Aluminium
Fitting Material Stainless Steel
Fitting Size 1/ 8” NPT
Fitting Type Female
IP Protection IP65 (NEMA 4)
Measurement Type Differential Pressure
Medium Water
Model PW2LN05BP
Mounting Panel
Operating Current 29 mA
Operating Humidity 0 to 90% RH, non-condensing
Operating Temperature -4 to 130°F (-10 to 55°C)
Output Specifications 4 to 20 mA
Outputs Analog output
Pressure Measurement Accuracy Range A, B and C: ±1% of F.S. Range D: ±2% of F.S.
Pressure Measurement Range 0 to 25 psi (0 to 1.7 bar) | 0 to 50 psi (0 to 3.5 bar) | 0 to 100 psi (0 to 7 bar) | 0 to 250 psi (0 to 17 bar)
Product Certification CE
Product Type Sensor
Range PW2
Standards EMC EN 61000-6-1
Supply Voltage DC Range 12 to 24 VDC
Warranty 5 years
Click here for complete specifications on the Veris PW2LN05BP

What's included with the Veris PW2LN05BP

  • Veris PW2LN05BP Pressure Transducer, 0 to 250 psig, NIST certificate

Ask a question about Veris PW2LN05BP Pressure Transducer, 0 to 250 psig, NIST certificate

Customer Reviews for the Veris PW2LN05BP

Veris PW2LN05BP Offers

The PW2LN05BP series 2-wire, 4 to 20 mA wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability. Easy to use and designed to provide exceptional installation savings, the PW2 series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.

Features

  • LCD Display
  • Operational Range: 0-250 psig
  • The jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Selectable differential units: psid or bard
  • Dual sensor design for improved overpressure tolerance, eliminates the requirement for a bypass valve assembly in most applications
  • Jumper-controlled electronic surge dampening for high stability
  • Pushbutton zero calibration - no trim pots to adjust, maintain accuracy and reduce callbacks with automatic zero calibration
  • 2-wire transmitter output
  • User-selectable output
  • NIST certified
  • 2 times of maximum full scale range proof pressure
  • 5 times of maximum full scale range burst pressure
  • Mounted bypass assembly


Optional Accessories: AA11, AA12, AA13

Veris PW2LN05BP Specifications

Application Zone Plant Room
Application Pump and Compressor Differential Pressure | Chiller Differential Pressure Monitoring
Brand Veris
Burst Pressure 1250 psi (85 bar)
Calibration Certificate NIST Certificate
Dimension Depth 2.6" (67 mm)
Dimension Height 12" (305 mm)
Dimension Width 8.7" (221 mm)
Display Size 0.7" x 1.4" (17 mm x 36 mm)
Display Type LCD
Electrical Wiring 2-wires (loop-powered)
Enclosure Material Powder Coated Aluminium
Fitting Material Stainless Steel
Fitting Size 1/ 8” NPT
Fitting Type Female
IP Protection IP65 (NEMA 4)
Measurement Type Differential Pressure
Medium Water
Model PW2LN05BP
Mounting Panel
Operating Current 29 mA
Operating Humidity 0 to 90% RH, non-condensing
Operating Temperature -4 to 130°F (-10 to 55°C)
Output Specifications 4 to 20 mA
Outputs Analog output
Pressure Measurement Accuracy Range A, B and C: ±1% of F.S. Range D: ±2% of F.S.
Pressure Measurement Range 0 to 25 psi (0 to 1.7 bar) | 0 to 50 psi (0 to 3.5 bar) | 0 to 100 psi (0 to 7 bar) | 0 to 250 psi (0 to 17 bar)
Product Certification CE
Product Type Sensor
Range PW2
Standards EMC EN 61000-6-1
Supply Voltage DC Range 12 to 24 VDC
Warranty 5 years