The TIF Instruments TIF7612 Handheld IR Laser Thermometer measures temperatures at a distance with a laser guide for improved aiming. Capable of measuring temperatures between -76 Degrees F to 932 Degrees F or -60 Degrees C to 500 Degrees C via IR with an adjustable 12:1 distance to target ratio.
Chracteristics: | TIF Instruments TIF7612 Handheld IR Laser Thermometer |
Measuring range: -76 Degrees F to 932 Degrees F or -60 Degrees C to 500 Degrees C | |
12:1 Distance to target ratio | |
Laser Guide for Accuracy | |
Low Battery Level Indicator | |
MIN/MAX/AVG/DIF Function Features | |
High and Low Temperature Alarms | |
Variable Emissivity |
Specifications: | TIF Instruments TIF7612 Infrared IR Laser Thermometer Pro |
Measurement Range: | -76 to +932 Degrees F (-60 to +500 Degrees C) |
Thermocouple Measurement Range: | -83.2 to +1999 Degrees F (-64 to +1400 Degrees C) |
Accuracy: Tobj=59-95 Degrees F (15-35 Degrees C) Tamb=77 Degrees F (25 Degrees C) | +/-1.8 Degrees F (1.0 Degree C) |
Accuracy: Tobj= -27-932 Degrees F (-33-500 Degrees C) Tamb= 73 Degrees F | +/-2% of reading or 4 Degrees F (2 Degrees C) whichever is greater |
Thermocouple Accuracy: | +/-1% of reading or 1.8 Degrees F (1 Degree C) whichever is greater (Test under Tamb=73+11 Degrees F [23+6 Degrees C]) |
Emissivity: | Adjustable |
Resolution: 14.2 Degrees F~199.9 Degrees F (-9.9~199.9 Degrees C): | 0.1 Degree F/C (1 Degree below 9.9 and above 199.9) |
Spectral Response: | 8 ~ 14μm |
Response Time (90%): | .5 sec |
Distance:Spot: | 12:1 |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: | TIF Instruments TIF7612 Infrared IR Laser Thermometer Pro |
Electrical: | Check temperature of high voltage equipment and transformers from a safe distance |
Detect heating of problem fuses, wires, insulators, connectors, splices, switches, neutrals | |
Overloads motors due to possible Harmonic currents | |
HVAC/R: | Furnace exteriors, steam traps, heat exchangers |
Take suction line temperatures for SUPERHEAT Ambient temperature | |
Ambient temperature | |
Outlet air | |
Inlet air | |
Refrigeration equipment, freezers and display cases AC Condenser Max temp look for blockages | |
Chiller input/output | |
Average over condenser coil for energy audit | |
Industrial: | Rotating motors and other machinery |
Motor starter relay contacts and overloads | |
Bearings | |
Energy surveys and Boiler operations and steam systems | |
Performance verifications of machinery and equipment | |
Food processing | |
Automotive: | Detect overheating electrical components, connectors and wiring harness |
Pinpoint radiator core restrictions | |
Temperature sensors | |
Catalytic converters | |
Exhaust systems | |
Tire Tread temperature | |
Battery temperature | |
Oil Temperature | |
Boiler operations and steam systems |