General Specifications: | Trend Networks LanTek IV Cable Certifier |
Battery: | Lithium ion, 7.4VDC, 6.6AH (48.84 Wh typical); Input: 12V/2A DC; Typical operating time: 8 hours (new battery running a Cat6 test every 2.5 minutes, full backlight); Charge time: <4 hours quick charge with battery removed from handset, <8 hours inside handset |
Input Power: | Handset: DC 12-15V, 2A |
Line/mains power adapters: | Input: AC 110-240V, 50/60Hz Output: 12 2500mA 5.5mm x 2.5mm x 12mm Center positive |
Display: | IPS, 480x854 pixel, 5” diagonal |
Connectivity: | Test module port: 120 pin ultra-low crosstalk module interface USC C (USB 2.0), USB A (USB 2.0), 3.5mm talk set jack, power/charging jack, integrated Wi-Fi (2.4/5 GHz bands) 802.11a/b/g/n (model available with Wi-Fi disabled). |
Input Methods: | Capacitive touchscreen, USB keyboard, USB mouse |
Frequency Range: | 1-500 or 1-3000 MHz, sweep defined by selected test standard |
CPU Module (Main Handset): | CPU: 1.0 GHz, 32 bit Cortex™ A9 processor, ARM 7 core. System memory: 512 MB RAM System storage: eMMC Flash 8 GB |
CPU Module (Remote Handset): | CPU: 900 MHz, 32 bit Cortex™ A7 processor, ARM 7 core System memory: 128 MB RAM System storage: eMMC Flash 8 GB |
Test Storage: | Non-volatile flash, storage capacity for 2500 tests with graphs |
Data Transfer: | Network transfer to cloud via Wi-Fi Export to USB flash drive. Supports drives up to 256 GB (FAT32 format required) |
Measurements: | Twisted Pair Copper Cabling: Wire map, DC loop resistance length, capacitance, NEXT, insertion loss, ACR-N, return loss, average impedance, propagation delay, delay skew, power sum NEXT, power sum ACR-N, ACR-F, power sum ACR-F, TCL (Transverse Conversion Loss), ELTCTL (Equal Level Transverse Conversion Transfer Loss, DC loop resistance, DC resistance unbalance Loss, DC loop resistance, DC resistance unbalance (pair-to-pair/intra-pair), Time Domain NEXT and Time Domain Return Loss fault finding identifies the location of NEXT and RL events.
Fibre Optic Cabling (optional FiberTEK IV test modules): Dual wavelength insertion loss (each fibre), length. Supported wavelengths: Multimode 850/1300nm, Single-mode 1310/1550nm. Fault location with integrated laser visual fault locator |
Supported Cable Types: | • TIA/EIA Category 3, 4, 5, 5E, 6, 6A and 8: 100O • ISO/IEC Class C, D, E, EA, F, FA and 8: 100O • OM1-OM5 multimode and OS1-OS2 single-mode fibre optic cable |
Test Interface: | • 120 pin ultra-low crosstalk connector |
Supported Connectors: | • TIA Cat 6/6A, ISO Class E/EA RJ-45 permanent link adapters • TIA Cat 8.1, ISO Class I/II RJ-45 permanent link adapters • TIA Cat 6/6A, ISO Class E/EA RJ-45 channel adapters • TIA Cat 8.1, ISO Class I/II RJ-45 channel adapters • TERA/GG45/EC7 (MMCPRO3000) Cat 8.2 universal adapters for channel and permanent link testing • SC/FC/ST fibre optic connectors included with FiberTEK IV kits. LC adapter kit optional |
Test Times: | Copper: 7 sec to 1000 MHz, 23 sec to 3000 MHz including required/optional tests. Fiber: 14 sec dual-wavelength, one direction. 28 sec, dual-wavelength, bi-directional. |
Wiremap distance to fault display resolution: | 10cm/3.9in |
Length Measurement: | Copper - Measurement range: 0-600m/0-1,960ft Fiber - Measurement range 0-10km/0-32,808ft Display resolution: 0.1m/1ft |
DC Resistance: | Measurement range: 0.02-200 ohms Display resolution: 0.1 ohms |
Propagation delay: | Measurement range: 1ns-1s Display resolution: 1ns |
RF measurements: | Accuracy: ISO/IEC 61935-1 Ed 5, ANSI/TIA-1152-A Display resolution: 0.1dB |
Optical Characteristics: | Typical output power: -20dBm 850nm, -15dB 1300nm, -7dBm 1310/1550nm Receiver sensitivity: -60dBm loss measurement, -45dBm loss & length measurement Encircled flux test cord insertion loss: <3.0dB each |
Operating Temperature: | 0°C to 45°C, non-condensing |
Storage Temperature: | -20°C to 70°C, non-condensing |
Vibration/Shock: | MIL-PRF-28800 F, Class 3 (met by design) |
User Interface Languages: | Chinese, English, French, German, Italian, Portuguese, Russian and Spanish |
Accuracy: | Certified by ETL to meet ANSI/TIA-1152-A Level 2G, IEC 61935-1 Level VI (3000 MHz model) 500 MHz model certified to Level IIIe |
Warranty: | Instrument: one (1) year from date of delivery Accessories: one (1) year from date of delivery Batteries: six (6) months from date of delivery |
PC Software: | TREND AnyWARE Cloud Web client – requires HTML 5 compatible browser TREND AnyWARE Desktop software; Requirements: Microsoft Windows 10 or higher, 2 GB RAM, 500MB hard disk + 1GB for every 1,500 Category 6 tests |
Dimensions: | Height/Width/Depth: 10in/5in/2.1in (25.4cm/12.7cm/5.3cm) Weight w/ Battery Installed: Display: 2.35 lbs/1.1kg Remote: 2.30 lbs/1.0kg |
Conformance: | • IEC 61010-1:2010 Ed 3 - Safety requirements for electrical equipment for measurement, control and laboratory use. • EN61326-1:2013 – Electrical equipment for measurement, control and laboratory use. EMC requirements. • EN55011:2009 + A2:2010 – Industrial, scientific and medical equipment. Radio frequency disturbance characteristics. • ENGl000-4-2:2009 - Electrostatic Discharge Immunity Test • EN61000-4-3:2006+A2:2010 - Radiated, radio-frequency, electromagnetic field immunity test • EN61000-4-4:2004+Al:2010 - Electrical Fast Transient / Burst Immunity Test • ENGl000-4-5:2006 - Surge Immunity Test • EN61000-4-6:2009 - Immunity to conducted disturbances, induced by radiofrequency fields • EN61000-4-11:2004 - Voltage dips, short interruptions and voltage variations immunity tests • Instrument: CE, C-Tick, FCC Part 15, Class A • Battery: DOT 49 CFR 173.185, UN Part IV – section 38.3 |
|