Replaced by UEi DL579
UEI DL479 TRMS Clamp Meter 600A AC for HVAC is designed to measure up to 600A AC current, 750V AC, 600V DC, resistance measurements up to 60MO, and DC microamps up to 2000µA. The UEi DL479 features true RMS measurements, diode testing, non-contact voltage detection, data hold, a built-in worklight, low battery indication, backlight, capacitance testing, temperature measurements via type k thermocouple, a convenient magnetic mount, and more.
UEI DL479 TRMS Clamp Meter 600A AC for HVAC | |
True RMS measurements | |
Measures up to 600A AC | |
Measures up to 750V AC and 600V DC | |
Resistance measurements up to 60MO | |
Measures DC microamps up to 2000µA | |
Diode testing | |
Features non-contact voltage detection | |
Continuity with audible beep | |
6000 count display | |
Data hold feature to freeze readings | |
Manual ranging option | |
Built-in worklight for dark environments | |
Audible voltage indication | |
Automatically shuts off when not in use | |
Indicates when battery is low | |
Capacitance testing up to 2000µF | |
Over molded to improve user grip | |
Built-in test lead storage | |
Automatic calibration | |
Backlit display | |
Temperature 14 to 752F (-10 to 400C) (Type k thermocouple) | |
Frequency/Duty cycle measurements | |
MIN/MAX function | |
Convenient magnetic mount | |
Great for motor or line current, control voltage or system board voltage checks, circuit continuity or specified resistance, flame safe guard, quick check of live wires, diode malfunctions/unbroken paths, and more | |
2 year limited warranty | |
Includes test leads with alligator clips, thermocouple temperature probe, zippered pouch, 2 AAA batteries, and manual |
Specifications: | UEI DL479 TRMS Clamp Meter 600A AC for HVAC | ||
AC Amps - Jaw Input | |||
Range | Resolution | Accuracy | Overload Protection |
60A | 0.01A | ±(2.0% +8 dgts) | 600V RMS |
600A | 0.1A | ||
True RMS Frequency range: Sine 50Hz to 400Hz Frequency width: 60Hz to 400Hz: 5% to 95% Frequency width: 400Hz to 4kHz: 15% to 85% | |||
AC Volts (45Hz to 400Hz) | |||
Range | Resolution | Accuracy | Overload Protection |
600mV | 0.1mV | ±(1.0% +3 dgts) | 1000V RMS |
6V | 1mV | ||
60V | 10mV | ||
600V | 100mV | ||
750V | 1.0V | ||
True RMS Frequency range: Sine 50Hz to 400Hz, Sine 50Hz to 400Hz Bandwidth: Sine = 0.5% error at 1.5kHz (max) Bandwidth: Square = 0.5% error at 0.1kHz (max) Bandwidth: Triangle = 0.5% error at 1.2kHz (max) | |||
DC Volts | |||
Range | Resolution | Accuracy | Overload Protection |
600mV | 0.1mV | ±(0.5% +4 dgts) | 1000V RMS |
6V | 1mV | ||
60V | 10mV | ||
600V | 100mV | ||
DC Low Amps | |||
Range | Resolution | Accuracy | Overload Protection |
600µA | 0.1µA | ±(1.2% +3 dgts) | 2000µA/600V RMS |
2000µA | 1µA | ||
Resistance | |||
Range | Resolution | Accuracy | Overload Protection |
600O | 0.1O | ±(0.8% +3 dgts) | 600V RMS |
6kO | 1O | ||
60kO | 10O | ||
600kO | 100O | ||
6MO | 0.001MO | ||
60MO | 0.01MO | ±(1.2% +3 dgts) | |
Frequency | |||
Range | Resolution | Accuracy | Overload Protection |
99.99Hz | 0.01Hz | ±(0.1% per+3 dgts) | 600V RMS |
999.9Hz | 0.1Hz | ||
9.999kHz | 0.001kHz | ||
Duty Cycle | |||
Range | Resolution | Accuracy | Overload Protection |
0.5% to 95% 60Hz to 400Hz | 0.1% | ±(0.2% per kHz +2.0% +2 dgts) | 600V RMS |
15% to 85% 400Hz to 2kHz | |||
Diode Test | |||
Range | Open Circuit | Test Current | Overload Protection |
4.0V | <3.0V DC | 1.30mA | 600V RMS |
Capacitance | |||
Range | Resolution | Accuracy | Overload Protection |
60nF | 0.01nF | ±(3.0% +5 dgts) | 600V RMS |
600nF | 0.1nF | ||
6.000µF | 0.001µF | ||
60.00µF | 0.01µF | ||
600.0µF | 0.1µF | ||
2000µF | 1µF | ||
Continuity | |||
Open Circuit | Response Time | Overload Protection | |
<1.0V | <50ms | 600V RMS | |
Temperature | |||
Range | Resolution | Accuracy | Overload Protection |
14° to 752°F | 0.1°F | ±(1.5% +3.6°F) | 600V RMS |
-10° to 400°C | 0.1°C | ±(1.5% +2.0°C) | |
Stated accuracy does not account for themocople accuaracy Sensitivity >2Vpp RMS | |||
Non-Contact Voltage | |||
On Voltage | |||
Approx. 25V AC |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: |
UEI DL479 TRMS Clamp Meter 600A AC for HVAC |
Security | |
Home theater | |
Electrical | |
HVAC | |
Etc. |
UEI DL479 TRMS Clamp Meter 600A AC for HVAC
"
Data Sheets
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet.pdf
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet (Français).pdf
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Data Sheet (Español).pdf
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Sell Sheet Data Sheet.pdf
Manuals
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual.pdf
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual (Français).pdf
UEI DL479 True RMS Clamp Meter 600A AC for HVAC/R - Manual (Español).pdf




Manuals



Related Items
(0)
Coming Soon
Free Shipping.
(0)
Coming Soon
Free Shipping.