Additel ADT878PC-700-B-110V Reference Dry Well Calibrator with Process Calibrator, 33 to 700°C, insert B, 110V

Model: ADT878PC-700-B-110V

Additel ADT878PC-700-B-110V Reference Dry Well Calibrator with Process Calibrator, 33 to 700°C, insert B, 110V

Model: ADT878PC-700-B-110V

Holding laboratory-grade stability and uniformity in a portable well, this reference dry well calibrator spans 33 to 700°C, displays within ±0.20°C to 425°C and ±0.25°C at 660°C, and reaches 700°C in 25 minutes. Insert B sets the hole pattern in the well. Process electronics read a reference probe and two devices under test, drive HART transmitters and log results as found and as left.

Holding laboratory-grade stability and uniformity in a portable well, this reference dry well calibrator spans 33 to 700°C, displays within ±0.20°C to 425°C and ±0.25°C at 660°C, and reaches 700°C in 25 minutes. Insert B sets the hole pattern in the well. Process electronics read a reference probe and two devices under test, drive HART transmitters and log results as found and as left.

Your Price $19966.00 USD
Availability 2 to 3 Weeks
Quantity

Additel ADT878PC-700-B-110V Offers

Features

  • Interchangeable metal insert sets the hole pattern, so one well serves many sensor diameters
  • Removable insert lifts out with the supplied tool while the well is still warm
  • Laboratory-grade uniformity is published at two immersion depths, 60 mm and 80 mm, so you can see how much stem matters
  • 6.5" color touch screen drives set point, auto step, ramp and soak without a PC
  • Reaches 700°C in 25 minutes
  • USB, Ethernet, Wi-Fi and Bluetooth allow remote control and data download
  • Eight display languages including English, French and Spanish
  • Process Calibrator option adds an external reference PRT input plus two measurement channels for devices under test
  • Channels read mA, voltage, switch, RTD and thermocouple, so the sensor and its transmitter are calibrated in one pass
  • HART communication reads, configures and calibrates HART transmitters
  • 24 V loop power drives a two-wire transmitter without a separate supply
  • Documented tasks store up to 1000 procedures with as-found and as-left results
  • Control the set point from the external reference instead of the internal sensor for the tightest achievable accuracy

Applications

  • Metrology laboratories needing bath-level stability without the fluid
  • Instrument technicians verifying process temperature transmitters on site
  • Calibration laboratories issuing accredited temperature certificates
  • Maintenance teams meeting scheduled recalibration intervals
  • Accredited providers realizing and maintaining a triple point of water cell

Additel ADT878PC-700-B-110V Specifications

Temperature Performance
Temperature Range at 23°C 33 to 700°C
Display Accuracy ±0.20°C at 33°C, ±0.20°C at 425°C, ±0.25°C at 660°C
Stability ±0.010°C at 100°C, ±0.020°C at 425°C, ±0.030°C at 700°C
Axial Uniformity at 60 mm (2.4") ±0.10°C at 100°C, ±0.25°C at 425°C, ±0.40°C at 700°C
Axial Uniformity at 80 mm (3.15") ±0.15°C at 100°C, ±0.30°C at 425°C, ±0.60°C at 700°C
Radial Uniformity ±0.025°C at 100°C, ±0.040°C at 425°C, ±0.060°C at 700°C
Loading Effect ±0.02°C at 100°C, ±0.05°C at 425°C, ±0.15°C at 700°C display sensor
Hysteresis 0.07°C (display sensor)
Resolution 0.001°C
Temperature Units °C, °F and K
Heating Time 25 minutes from 23 to 700°C
Cooling Time 30 minutes from 700 to 100°C, 15 minutes from 100 to 50°C
Typical Time to Stability 10 minutes
Well and Insert
Immersion Depth 7.60" (193 mm)
Insert Outside Diameter 1.21" (30.8 mm)
Insert Supplied ADT110-878-H-INSERT-B
Process Calibrator
Reference Probe Input 6-pin Lemo smart connector, 4-wire PRT
Reference Readout Accuracy ±0.009°C at -40°C, ±0.017°C at 155°C, ±0.030°C at 420°C, ±0.042°C at 660°C
Reference Resistance Range 0 to 400 Ω
Reference Resistance Accuracy ±0.002 Ω from 0 to 50 Ω, ±40 ppm of reading from 50 to 400 Ω
Reference Characterizations ITS-90, CVD, IEC-751, resistance
RTD Channels 2, each accepting 2, 3 or 4-wire RTDs
RTD Measurement Accuracy ±0.002 Ω from 0 to 25 Ω, ±0.008% of reading from 25 Ω to 4 kΩ
RTD Characterizations PT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120
Thermocouple Channels 2, mini TC terminals accepting S, R, K, B, N, E, J, T, C, D, G, L and U
Thermocouple Accuracy, Type K ±0.13°C at 0°C, ±0.16°C at 155°C, ±0.19°C at 350°C, ±0.25°C at 660°C
Thermocouple Range -75 to 75 mV
Thermocouple Voltage Accuracy 0.02% of reading + 5 µV
Internal Cold Junction Accuracy ±0.35°C from 0 to 50°C ambient
Current Range -30 to 30 mA
Current Accuracy 0.02% of reading + 2 µA
Voltage Ranges -12 to 12 V and -30 to 30 V
Voltage Accuracy ±0.02% of reading + 2 mV
Switch Test Mechanical or electrical
Loop Power Output 24 V ±10%, 60 mA maximum
HART Communication Read, configure and calibrate HART devices
Documentation Up to 1000 tasks storing 10 results each, with as-found and as-left data
General
Display 6.5" (165 mm) color touch screen
Communication USB-A, USB-B, RJ45, Wi-Fi, Bluetooth
Dimensions 6.69 x 13.58 x 13.0" (170 x 345 x 330 mm)
Weight 21.4 lb (9.7 kg)
Power Requirements 90 to 254 V AC, 45 to 65 Hz, 1400 W
Environmental Conditions 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m
Storage Conditions -20 to 60°C
Mechanical Testing Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm)
Click here for complete specifications on the Additel ADT878PC-700-B-110V

What's included with the Additel ADT878PC-700-B-110V

  • Reference Dry Well Calibrator
  • ISO 17025 Accredited Calibration Certificate
  • Insert, 1 selected
  • Insert Removal Tool
  • Thermal Shield
  • Power Cable
  • USB Cable
  • Test Leads, 2 sets of 2
  • One-Year Warranty

Ask a question about Additel ADT878PC-700-B-110V Reference Dry Well Calibrator with Process Calibrator, 33 to 700°C, insert B, 110V

Customer Reviews for the Additel ADT878PC-700-B-110V

Additel ADT878PC-700-B-110V Offers

Features

  • Interchangeable metal insert sets the hole pattern, so one well serves many sensor diameters
  • Removable insert lifts out with the supplied tool while the well is still warm
  • Laboratory-grade uniformity is published at two immersion depths, 60 mm and 80 mm, so you can see how much stem matters
  • 6.5" color touch screen drives set point, auto step, ramp and soak without a PC
  • Reaches 700°C in 25 minutes
  • USB, Ethernet, Wi-Fi and Bluetooth allow remote control and data download
  • Eight display languages including English, French and Spanish
  • Process Calibrator option adds an external reference PRT input plus two measurement channels for devices under test
  • Channels read mA, voltage, switch, RTD and thermocouple, so the sensor and its transmitter are calibrated in one pass
  • HART communication reads, configures and calibrates HART transmitters
  • 24 V loop power drives a two-wire transmitter without a separate supply
  • Documented tasks store up to 1000 procedures with as-found and as-left results
  • Control the set point from the external reference instead of the internal sensor for the tightest achievable accuracy

Applications

  • Metrology laboratories needing bath-level stability without the fluid
  • Instrument technicians verifying process temperature transmitters on site
  • Calibration laboratories issuing accredited temperature certificates
  • Maintenance teams meeting scheduled recalibration intervals
  • Accredited providers realizing and maintaining a triple point of water cell

Additel ADT878PC-700-B-110V Specifications

Temperature Performance
Temperature Range at 23°C 33 to 700°C
Display Accuracy ±0.20°C at 33°C, ±0.20°C at 425°C, ±0.25°C at 660°C
Stability ±0.010°C at 100°C, ±0.020°C at 425°C, ±0.030°C at 700°C
Axial Uniformity at 60 mm (2.4") ±0.10°C at 100°C, ±0.25°C at 425°C, ±0.40°C at 700°C
Axial Uniformity at 80 mm (3.15") ±0.15°C at 100°C, ±0.30°C at 425°C, ±0.60°C at 700°C
Radial Uniformity ±0.025°C at 100°C, ±0.040°C at 425°C, ±0.060°C at 700°C
Loading Effect ±0.02°C at 100°C, ±0.05°C at 425°C, ±0.15°C at 700°C display sensor
Hysteresis 0.07°C (display sensor)
Resolution 0.001°C
Temperature Units °C, °F and K
Heating Time 25 minutes from 23 to 700°C
Cooling Time 30 minutes from 700 to 100°C, 15 minutes from 100 to 50°C
Typical Time to Stability 10 minutes
Well and Insert
Immersion Depth 7.60" (193 mm)
Insert Outside Diameter 1.21" (30.8 mm)
Insert Supplied ADT110-878-H-INSERT-B
Process Calibrator
Reference Probe Input 6-pin Lemo smart connector, 4-wire PRT
Reference Readout Accuracy ±0.009°C at -40°C, ±0.017°C at 155°C, ±0.030°C at 420°C, ±0.042°C at 660°C
Reference Resistance Range 0 to 400 Ω
Reference Resistance Accuracy ±0.002 Ω from 0 to 50 Ω, ±40 ppm of reading from 50 to 400 Ω
Reference Characterizations ITS-90, CVD, IEC-751, resistance
RTD Channels 2, each accepting 2, 3 or 4-wire RTDs
RTD Measurement Accuracy ±0.002 Ω from 0 to 25 Ω, ±0.008% of reading from 25 Ω to 4 kΩ
RTD Characterizations PT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120
Thermocouple Channels 2, mini TC terminals accepting S, R, K, B, N, E, J, T, C, D, G, L and U
Thermocouple Accuracy, Type K ±0.13°C at 0°C, ±0.16°C at 155°C, ±0.19°C at 350°C, ±0.25°C at 660°C
Thermocouple Range -75 to 75 mV
Thermocouple Voltage Accuracy 0.02% of reading + 5 µV
Internal Cold Junction Accuracy ±0.35°C from 0 to 50°C ambient
Current Range -30 to 30 mA
Current Accuracy 0.02% of reading + 2 µA
Voltage Ranges -12 to 12 V and -30 to 30 V
Voltage Accuracy ±0.02% of reading + 2 mV
Switch Test Mechanical or electrical
Loop Power Output 24 V ±10%, 60 mA maximum
HART Communication Read, configure and calibrate HART devices
Documentation Up to 1000 tasks storing 10 results each, with as-found and as-left data
General
Display 6.5" (165 mm) color touch screen
Communication USB-A, USB-B, RJ45, Wi-Fi, Bluetooth
Dimensions 6.69 x 13.58 x 13.0" (170 x 345 x 330 mm)
Weight 21.4 lb (9.7 kg)
Power Requirements 90 to 254 V AC, 45 to 65 Hz, 1400 W
Environmental Conditions 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m
Storage Conditions -20 to 60°C
Mechanical Testing Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm)
Click here for complete specifications on the Additel ADT878PC-700-B-110V

What's included with the Additel ADT878PC-700-B-110V

  • Reference Dry Well Calibrator
  • ISO 17025 Accredited Calibration Certificate
  • Insert, 1 selected
  • Insert Removal Tool
  • Thermal Shield
  • Power Cable
  • USB Cable
  • Test Leads, 2 sets of 2
  • One-Year Warranty