This is a versatile handheld optical loss test set that integrates a power meter and quad-wavelength laser sources (1310, 1490, 1550, and 1625 nm). With an InGaAs detector, ISO/IEC 17025 traceable calibration, and rugged design, it is ideal for FTTH, telecom, and broadband certification, providing accurate single-direction loss testing and easy PC-based reporting.
This is a versatile handheld optical loss test set that integrates a power meter and quad-wavelength laser sources (1310, 1490, 1550, and 1625 nm). With an InGaAs detector, ISO/IEC 17025 traceable calibration, and rugged design, it is ideal for FTTH, telecom, and broadband certification, providing accurate single-direction loss testing and easy PC-based reporting.
Features
Detector Type | InGaAs |
Response Wavelength | 780 to 1700 nm |
Calibration Wavelengths | 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
Power Range | +10 to -70 dBm (depending on λ) |
Tone and Autotest Sensitivity | -45 to -50 dBm |
Linearity | 0.04 dB (typical) |
Calibration Accuracy | ±1% (0.06 dB) |
Polarization Sensitivity | <0.05 dB (APC connectors) |
Total Uncertainty | 0.3 dB |
Laser Output Wavelengths | 1310, 1490, 1550, 1625 nm (APC) |
Output Power | -3 dBm (nominal, SMF) |
Short-Term Stability | 0.04 to 0.06 dB (15 minutes, ±2°C) |
Stability Over Temp | 0.6 dB (typical) |
Reconnection Repeatability | 0.1 dB at 95% confidence |
Modulated Output | 270 Hz 1 kHz 2 kHz ±2% 12 Multi-Fiber ID tones |
Memory | 1000 test results Unlimited with USB key |
Interfaces | Micro-USB for power/software USB-A for memory key |
Power | 2 × AA Alkaline NiMH (USB rechargeable) |
Battery Life | 80 to 90 hours typical in Autotest mode |
Display | 2.9 × 2.2" (74 × 55 mm) high-contrast LCD, backlit |
Case | Polycarbonate with rubber edges Moisture resistant 1 m drop-tested |
Warranty | 3 years |
Dimensions | 7.5 × 4.1 × 1.4" (190 × 105 × 35 mm) |
Weight | 0.93 lbs (420 g) |
Shipping | 3.3 lbs (1.5 kg) |
Detector Type | InGaAs |
Response Wavelength | 780 to 1700 nm |
Calibration Wavelengths | 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
Power Range | +10 to -70 dBm (depending on λ) |
Tone and Autotest Sensitivity | -45 to -50 dBm |
Linearity | 0.04 dB (typical) |
Calibration Accuracy | ±1% (0.06 dB) |
Polarization Sensitivity | <0.05 dB (APC connectors) |
Total Uncertainty | 0.3 dB |
Laser Output Wavelengths | 1310, 1490, 1550, 1625 nm (APC) |
Output Power | -3 dBm (nominal, SMF) |
Short-Term Stability | 0.04 to 0.06 dB (15 minutes, ±2°C) |
Stability Over Temp | 0.6 dB (typical) |
Reconnection Repeatability | 0.1 dB at 95% confidence |
Modulated Output | 270 Hz 1 kHz 2 kHz ±2% 12 Multi-Fiber ID tones |
Memory | 1000 test results Unlimited with USB key |
Interfaces | Micro-USB for power/software USB-A for memory key |
Power | 2 × AA Alkaline NiMH (USB rechargeable) |
Battery Life | 80 to 90 hours typical in Autotest mode |
Display | 2.9 × 2.2" (74 × 55 mm) high-contrast LCD, backlit |
Case | Polycarbonate with rubber edges Moisture resistant 1 m drop-tested |
Warranty | 3 years |
Dimensions | 7.5 × 4.1 × 1.4" (190 × 105 × 35 mm) |
Weight | 0.93 lbs (420 g) |
Shipping | 3.3 lbs (1.5 kg) |